Loudness discomfort level: selected methods and stimuli
The DOI matches its Crossref record.
Abstract
Two investigations were conducted (i) to determine a reliable procedure for obtaining loudness discomfort levels (LDL) and (ii) to observe the effects of frequency on the LDL. Three psychophysical methods were compared in the measurement of the LDL—a programmed method of constant stimuli, the method of adjustment, and a tracking method. The method of constants provided the most reliable judgments over six trials for a 1000-Hz stimulus. The LDL was then measured utilizing the method of constants for pure tones at octave frequencies from 125 to 4000 Hz, and for a wide and narrow band of noise. The LDLs (in dB SPL) were highest at low frequencies (through 500 Hz) and relatively constant for 1000, 2000, 4000 Hz, and the wide-band noise. The relatively high LDLs in the low frequencies are explained on the basis of difference in the intensity level for low frequencies measured in a conventional 6 cm3 coupler and that observed in the ear canal when a supra-aural earphone is fitted on the head. When a correction is made for this difference the LDL results across frequency compared closely with results from loudness-contour studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sherlock, L. P., & Formby, C. (2005) · Journal of the American Academy of Audiology · doi:10.3766/jaaa.16.2.4 · Cited by 127
Hyperacusis: major research questions
Baguley, D. M., & Hoare, D. J. (2018) · HNO · doi:10.1007/s00106-017-0464-3 · Cited by 78
“There are techniques for the determination of the loudest sound an individual can tolerate, or is comfortable with, and these include loudness discomfort levels and loudness scaling techniques [1, 31].”
BackgroundLoudness Discomfort Level and Reliability as a Function of Instructional Set
Bornstein, S. P., & Musick, F. E. (1993) · Scandinavian Audiology · doi:10.3109/01050399309046028 · Cited by 29
Metadata
- Authors
- Morgan, D. E., Wilson, R. H., & Dirks, D. D.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 1974-08-01
- Volume
- 56
- Issue
- 2
- Pages
- 577-581
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2095087701
- Cited by
- 36
- References
- 0
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Loudness discomfort level: selected methods and stimuli. https://app.cochat.ai/papers/10.1121/1.1903293
- The paper
- Morgan, D. E., Wilson, R. H., & Dirks, D. D. (1974). Loudness discomfort level: selected methods and stimuli. The Journal of the Acoustical Society of America. https://doi.org/10.1121/1.1903293
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.