New Method of Measuring Reverberation Time
Open accessThe DOI matches its Crossref record.
Abstract
A new method of measuring reverberation time is described. The method uses short pulses of acoustic energy, such as pistol shots or tone bursts, to excite the enclosure. An integral over the response of the enclosure yields, in a single measurement, the average of infinitely many decay curves that would be obtained with random noise as the excitation signal. The smooth decay curves resulting from the new method improve the accuracy of reverberation-time measurements and facilitate the detection of nonexponential decays. In a recent publication [J. Acoust. Soc. Am. 37, 409–412 (1965)], the fundamental relationship between decay curves obtained from impulse and noise excitations, on which the new method is based, was proved. In this talk, progress with instrumenting the new method is described. Results obtained in a large concert hall are described subsequently (B. S. Atal, M. R. Schroeder, G. M. Sessler, and J. E. West. Paper J5, this meeting).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
(2018) · Springer Series on Touch and Haptic Systems · doi:10.1007/978-3-319-58316-7 · Cited by 60
Metadata
- Authors
- Schroeder, M. R.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 1965-06-01
- Volume
- 37
- Issue
- 6_Supplement
- Pages
- 1187-1188
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W4251733995
- Cited by
- 159
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.