CoChat

Intervention for restricted dynamic range and reduced sound tolerance

Formby, Charles, Hawley, Monica, Sherlock, Laguinn, Gold, Susan, Segar, Allyson, Gmitter, Christine, Cannavo, Justine · 2008 · The Journal of the Acoustical Society of America

The DOI matches its Crossref record.

Abstract

Hyperacusis is an abnormal condition of sound intolerance that may cause some persons to reject amplified sound from their hearing aids. A significant secondary benefit reported for many patients receiving Tinnitus Retraining Therapy (TRT) is increased Loudness Discomfort Levels (LDLs). TRT involves both counseling and sound therapy (i.e., daily exposure to soft sound from bilateral noise generators (NGs)). We implemented a randomized, double-blind, placebo-controlled clinical trial to assess the efficacy of TRT as an intervention to improve sound tolerance in hearing-aid eligible persons with hyperacusis and/or restricted dynamic ranges. Subjects were assigned to one of four treatment groups: 1) full treatment, both counseling and NGs, 2) counseling and placebo NGs, 3) NGs without counseling, and 4) placebo NGs without counseling. They were evaluated at least monthly, typically for five months or more, on a variety of audiometric tests, including LDLs, the Contour Test for Loudness, and word recognition measured at comfortable and loud levels. Over 80% of the subjects assigned to full treatment achieved significant benefit (defined as shifts of greater than 10 dB in LDLs or the Contour Test uncomfortable level); whereas, most subjects assigned to a partial treatment group did not benefit from their treatment. [Supported by NIH].

Overview

Integrity signals

Registry

Crossref · 10.1121/1.2935164

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Still being checked.

Cited by

See all 15

Metadata

Authors
Formby, C., Hawley, M., Sherlock, L., Gold, S., Segar, A., Gmitter, C., & Cannavo, J.
Affiliations
  • University of Alabama (US)
  • University of Maryland, Baltimore (US)
  • University of Maryland, College Park (US)
Venue
The Journal of the Acoustical Society of America
Published
2008-05-01
Volume
123
Issue
5_Supplement
Pages
3717-3717
ISSN
  • 0001-4966 (ISSN-L)
  • 1520-8524
OpenAlex
W4255809882
Cited by
15
References
0
Citations by year
2025: 3 · 2024: 3 · 2022: 1 · 2021: 2 · 2018: 1 · 2017: 1 · 2012: 1
Type
conference abstract
Language
en
Open access
closed
Locations
The Journal of the Acoustical Society of America (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Sensory Systems › Hearing, Cochlea, Tinnitus, Genetics
  • Health Sciences › Health Professions › Speech and Hearing › Hearing Loss and Rehabilitation
  • Physical Sciences › Physics and Astronomy › Acoustics and Ultrasonics › Noise Effects and Management
Keywords
hyperacusis, tinnitus retraining therapy, loudness discomfort level, sound tolerance, noise generator, sound therapy, counseling, hearing aids, word recognition, tinnitus

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intervention for restricted dynamic range and reduced sound tolerance. https://app.cochat.ai/papers/10.1121/1.2935164
The paper
Formby, C., Hawley, M., Sherlock, L., Gold, S., Segar, A., Gmitter, C., & Cannavo, J. (2008). Intervention for restricted dynamic range and reduced sound tolerance. The Journal of the Acoustical Society of America. https://doi.org/10.1121/1.2935164

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.