Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 290

The DOI matches its Crossref record.

On cochlear encoding: Potentialities and limitations of the reverse-correlation technique

de Boer, E., de Jongh, H. R.·1978·The Journal of the Acoustical Society of America

Abstract

This paper presents a description of the interrelation between two major properties of the responses recordable from auditory nerve fibers: frequency selectivity and partial synchrony between stimulus and response. In the course of this work the influence of nonlinearity on the cochlear encoding process can be assessed. The theory of the reverse-correlation technique is derived in a most general way. It is based on a model in which a filter—assumed to be linear—is followed by a stochastic pulse generator—the probability of producing an output pulse being an instantaneous but nonlinear function of its input signal. Insofar as such a model represents stimulus transformations in a primary auditory neuron, the technique can be applied to the responses recorded from an auditory nerve fiber. Several illustrative examples of experimental reverse-correlation functions−abbreviated: revcor functions—are presented and discussed. These functions have the general character of impulse responses of sharp bandpass filters. They show very little phase modulation. For noise stimuli of up to 70 dB per third octave the revcor functions are almost invariant. Above that level some (but not all) of the revcor functions show a loss of frequency selectivity. If a nerve fiber can be contacted for a sufficiently long time, it is possible to compare the response with that of a model filter, in which the revcor function of that fiber is substituted as its impulse response. The output signal of the model filter is shown to be a very good predictor of the firing probability of the fiber under study. This property is demonstrated for noise as well as for tone stimuli. There is surprisingly little evidence of nonlinear filtering in these results. This so-called simulation method can also be applied when the stimulus is switched on and off. The results show, apart from effects due to filtering, clear manifestations of fast adaptation. Again, the filtering appears to be independent of the latter effect. It is concluded that for wide-band noise and single-tone signals the firing probability is predominantly controlled by a linearly filtered version of the acoustical stimulus; this constitutes the principle of specific coding. The conspicuous absence of nonlinear effects in the results can partly be explained in terms of the response properties of a class of networks in which sharp filtering occurs after the generation of nonlinear distortion products. It can then be predicted that this property will hold only for wide-band and tonal stimuli. That our results show so little evidence of cochlear distortion appears to be a property of signal transformations and is not due to linearization tendencies of the experimental method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1121/1.381704

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 290

Metadata

Authors
de Boer, E., & de Jongh, H. R.
Venue
The Journal of the Acoustical Society of America
Published
1978-01-01
Volume
63
Issue
1
Pages
115-135
ISSN
  • 0001-4966 (ISSN-L)
  • 1520-8524
OpenAlex
W2167499516
Cited by
290
References
0
FWCI
6.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: On cochlear encoding: Potentialities and limitations of the reverse-correlation technique. https://app.cochat.ai/papers/10.1121/1.381704
The paper
de Boer, E., & de Jongh, H. R. (1978). On cochlear encoding: Potentialities and limitations of the reverse-correlation technique. The Journal of the Acoustical Society of America. https://doi.org/10.1121/1.381704

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.