Cited by 222Hearing, Cochlea, Tinnitus, GeneticsNeuroscience and Music PerceptionHearing Loss and Rehabilitation

The DOI matches its Crossref record.

Directional sensitivity of sound-pressure levels in the human ear canal

Middlebrooks, John C., Makous, James C., Green, David M.·1989·The Journal of the Acoustical Society of America

Abstract

Changes in sound pressures measured in the ear canal are reported for broadband sound sources positioned at various locations about the subject. These location-dependent pressures are one source of acoustical cues for sound localization by human listeners. Sound source locations were tested with horizontal and vertical resolution of 10°. Sound levels were measured with miniature microphones placed inside the two ear canals. Although the measured amplitude spectra varied with the position of the microphone in the ear canal, it is shown that the directional sensitivity at any particular frequency of the broadband stimulus is independent of microphone position anywhere within the ear canal. At any given frequency, the distribution of sound pressures as a function of sound source location formed a characteristic spatial pattern comprising one or two discrete areas from which sound sources produced maximum levels in the ear canal. The locations of these discrete areas varied in horizontal and vertical location according to sound frequency. For example, around 8 kHz, two areas of maximum sensitivity typically were found that were located laterally and were separated from each other vertically, whereas, around 12 kHz, two such areas were found located on the horizontal plane and separated horizontally. The spatial patterns of sound levels were remarkably similar among different subjects, although some frequency scaling was required to accommodate for differences in the subjects’ physical sizes. Interaural differences in sound-pressure level (ILDs) at frequencies below about 8 kHz tended to increase monotonically with increasing distance of the sound source from the frontal midline and tended to be relatively constant as a function of vertical source location. At higher frequencies, however, ILDs varied both with the horizontal and with the vertical location of the sound source. At some frequencies, asymmetries between the left and right ears in a given subject resulted in substantial ILDs even for midline sound sources. These results indicate the types of horizontal and vertical spatial information that are available from sound level cues over various ranges of frequency and, within a small subject population, indicate the nature of intersubject variability.

Overview

Integrity signals

Registry

Crossref · 10.1121/1.398224

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Still being checked.

Cited by

Sorted by citations

Metadata

Authors
Middlebrooks, J. C., Makous, J. C., & Green, D. M.
Affiliations
  • University of Florida Health (US)
  • University of Florida (US)
Venue
The Journal of the Acoustical Society of America
Published
1989-07-01
Volume
86
Issue
1
Pages
89-108
ISSN
  • 0001-4966 (ISSN-L)
  • 1520-8524
OpenAlex
W2015706719
Cited by
222
References
0
Citations by year
2026: 2 · 2025: 3 · 2024: 6 · 2023: 6 · 2022: 5 · 2021: 4 · 2020: 3 · 2019: 6 · 2018: 2 · 2017: 6 · 2016: 10 · 2015: 6 · 2014: 9 · 2013: 7 · 2012: 6
FWCI
2.82
Type
journal article
Language
en
Open access
closed
Locations
  • The Journal of the Acoustical Society of America (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (5r29ns025022-02)
  • National Institute of Neurological Disorders and Stroke (R29 NS25022)
Topics
  • Life Sciences › Neuroscience › Sensory Systems › Hearing, Cochlea, Tinnitus, Genetics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Neuroscience and Music Perception
  • Health Sciences › Health Professions › Speech and Hearing › Hearing Loss and Rehabilitation
Keywords
ear canal acoustics, sound localization, interaural level difference, directional sensitivity, sound pressure level, broadband sound sources, interaural asymmetry, interindividual variability, spatial cues, frequency dependence
MeSH terms
Acoustic Stimulation, Adult, Auditory Perception, Ear Canal, Female, Humans, Male, Sound, Sound Localization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review