Temporal modulation transfer functions in patients with cochlear implants
The DOI matches its Crossref record.
Abstract
Thresholds for the detection of amplitude modulation were measured in cochlear implant patients as a function of modulation frequency. Three types of threshold measures were taken: detection of amplitude modulation, detection of low-frequency sinusoidal current waveforms, and detection of beats in two-tone complexes. The temporal modulation transfer function (TMTF), defined as the plot of modulation detection thresholds as a function of modulation frequency, show low-pass filter characteristics with similar cutoff frequencies for all three tasks. The similarity of these three measures suggests a common temporal mechanism. While modulation detection differs somewhat in normal-hearing and implanted listeners, both exhibit the same general characteristics. The TMTFs are low pass with a cutoff frequency near 70 Hz for normal-hearing listeners and near 140 Hz for implanted listeners. Patients with cochlear implants can best detect temporal modulation at modulation frequencies below 300 Hz, and are most sensitive to 80- to 100-Hz modulation. At high carrier levels many implant patients could detect smaller modulation amplitudes than normal-hearing listeners, a finding that is consistent with the smaller intensity DLs for some implanted listeners at high levels. These results demonstrate that, while implant listeners cannot discriminate steady-state, high-frequency stimuli, speech information might be conveyed by the envelope of the high-frequency components of speech.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
“Basic psychophysical performance in cochlear implants: (A) Loudness growth as a function of current level from three studies [67]; (B) Pitch estimate as a function of electric stimulation rate ( -axis) and place (symbols) [51]; (C) Spatial tuning curves in a cochlear implant user (squares superimposed with the two sha…”
BackgroundMethodZeng, F.-G. (2004) · Trends in Amplification · doi:10.1177/108471380400800102 · Cited by 401
Music Perception with Temporal Cues in Acoustic and Electric Hearing
Kong, Y.-Y., Cruz, R., Jones, J. A., & Zeng, F.-G. (2004) · Ear and Hearing · doi:10.1097/01.aud.0000120365.97792.2f · Cited by 377
Temporal pitch in electric hearing
Zeng, F.-G. (2002) · Hearing Research · doi:10.1016/s0378-5955(02)00644-5 · Cited by 314
Temporal processing and speech recognition in cochlear implant users
Fu, Q.-J. (2002) · NeuroReport · doi:10.1097/00001756-200209160-00013 · Cited by 237
Relative contributions of spectral and temporal cues for phoneme recognition
Xu, L., Thompson, C. S., & Pfingst, B. E. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1886405 · Cited by 237
Speech recognition with altered spectral distribution of envelope cues
Shannon, R. V., Zeng, F.-G., & Wygonski, J. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.423774 · Cited by 193
Self-citationBucher, S. F., Dieterich, M., Wiesmann, M., Weiss, A., Zink, R., Yousry, T. A., & Brandt, T. (1998) · Annals of Neurology · doi:10.1002/ana.410440118 · Cited by 169
Metadata
- Authors
- Shannon, R. V.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 1992-04-01
- Volume
- 91
- Issue
- 4
- Pages
- 2156-2164
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2057012258
- Cited by
- 212
- References
- 0
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.