The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Auditory localization of nearby sources. Head-related transfer functions
Abstract
Although researchers have long recognized the unique properties of the head-related transfer function (HRTF) for nearby sources (within 1 m of the listener’s head), virtually all of the HRTF measurements described in the literature have focused on source locations 1 m or farther from the listener. In this study, HRTFs for sources at distances from 0.12 to 1 m were calculated using a rigid-sphere model of the head and measured using a Knowles Electronic Manikin for Acoustic Research (KEMAR) and an acoustic point source. Both the calculations and the measurements indicate that the interaural level difference (ILD) increases substantially for lateral sources as distance decreases below 1 m, even at low frequencies where the ILD is small for distant sources. In contrast, the interaural time delay (ITD) is roughly independent of distance even when the source is close. The KEMAR measurements indicate that the direction of the source relative to the outer ear plays an important role in determining the high-frequency response of the HRTF in the horizontal plane. However, the elevation-dependent characteristics of the HRTFs are not strongly dependent on distance, and the contribution of the pinna to the HRTF is independent of distance beyond a few centimeters from the ear. Overall, the results suggest that binaural cues play an important role in auditory distance perception for nearby sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The dominant role of low-frequency interaural time differences in sound localization
Wightman, F. L., & Kistler, D. J. (1992) · The Journal of the Acoustical Society of America · doi:10.1121/1.402445 · Cited by 752
Headphone simulation of free-field listening. I: Stimulus synthesis
Wightman, F. L., & Kistler, D. J. (1989) · The Journal of the Acoustical Society of America · doi:10.1121/1.397557 · Cited by 674
Gardner, W. G., & Martin, K. D. (1995) · The Journal of the Acoustical Society of America · doi:10.1121/1.412407 · Cited by 558
Transformation of sound pressure level from the free field to the eardrum in the horizontal plane
Shaw, E. A. G. (1974) · The Journal of the Acoustical Society of America · doi:10.1121/1.1903522 · Cited by 471
Model for the interaural time differences in the azimuthal plane
Kuhn, G. F. (1977) · The Journal of the Acoustical Society of America · doi:10.1121/1.381498 · Cited by 411
Head-Related Transfer Functions of Human Subjects
Møller, H., Sørensen, M. F., Hammershøi, D., & Jensen, C. B. (1995) · VBN Forskningsportal (Aalborg Universitet) · Cited by 291
Transformation characteristics of the external human ear
Mehrgardt, S., & Mellert, V. (1977) · The Journal of the Acoustical Society of America · doi:10.1121/1.381470 · Cited by 251
Directional sensitivity of sound-pressure levels in the human ear canal
Middlebrooks, J. C., Makous, J. C., & Green, D. M. (1989) · The Journal of the Acoustical Society of America · doi:10.1121/1.398224 · Cited by 222
Carlile, S., & Pralong, D. (1994) · The Journal of the Acoustical Society of America · doi:10.1121/1.409965 · Cited by 72
Cited by
Mechanisms of Sound Localization in Mammals
Grothe, B., Pecka, M., & McAlpine, D. (2010) · Physiological Reviews · doi:10.1152/physrev.00026.2009 · Cited by 949
Listener weighting of cues for lateral angle: The duplex theory of sound localization revisited
Macpherson, E. A., & Middlebrooks, J. C. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1471898 · Cited by 414
Where is 'where' in the human auditory cortex?
Zatorre, R. J., Bouffard, M., Ahad, P., & Belin, P. (2002) · Nature Neuroscience · doi:10.1038/nn904 · Cited by 344
Assessing auditory distance perception using virtual acoustics
Zahorik, P. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1458027 · Cited by 303
Kolarik, A. J., Moore, B. C. J., Zahorik, P., Cirstea, S., & Pardhan, S. (2016) · Attention, Perception, & Psychophysics · doi:10.3758/s13414-015-1015-1 · Cited by 297
Metadata
- Authors
- Brungart, D. S., & Rabinowitz, W. M.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 1999-09-01
- Volume
- 106
- Issue
- 3
- Pages
- 1465-1479
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2045261700
- Cited by
- 387
- References
- 9
- FWCI
- 17.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.