The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Determination of shear rate and viscosity from batch mixer data
Abstract
A general analysis allowing the determination of shear rate and viscosity from batch mixer rotor speed and torque data is presented. The batch mixer was represented by two effective adjacent sets of concentric cylinders exerting the same torque as that obtained from the batch mixer. The effective internal radius was determined through a general procedure for calibration using non-Newtonian fluid. The effective equivalent internal radius, Ri, was determined for different polymers and processing conditions. The results revealed that Ri is a universal quantity practically insensitive to the nature and to the rheological behavior of the fluid under mixing. In the case of small gaps, it was found that there is a special position in the gap where the effective internal radius, the shear rate and viscosity are independent of rheological characteristics of the fluid under mixing. This validates the Newtonian approximation previously used by Goodrich and Porter to extract the shear rate-viscosity dependence from batch mixer data. The technique was tested on seven different amorphous and semicrystalline polymers and the results were found to be in reasonable agreement with the data obtained independently with cone-and-plate and capillary rheometers. Contributions of both shear stress between the two cylinders and the stress generated at the wall were evaluated. The latter was found predominant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Morphology development during the initial stages of polymer-polymer blending
SCOTT, C. (1995) · Polymer · doi:10.1016/0032-3861(95)91554-k · Cited by 292
Morphology‐processing relationships in polyethylene‐polyamide blends
Serpe, G., Jarrin, J., & Dawans, F. (1990) · Polymer Engineering & Science · doi:10.1002/pen.760300908 · Cited by 274
Comparison of Methods for Calculating Shear Rates in Coaxial Viscometers
Yang, T. M. T., & Krieger, I. M. (1978) · Journal of Rheology · doi:10.1122/1.549483 · Cited by 90
Scott, C. E., & Joung, S. K. (1996) · Polymer Engineering and Science · doi:10.1002/pen.10563 · Cited by 51
Cited by
Sinha Ray, S., Pouliot, S., Bousmina, M., & Utracki, L. A. (2004) · Polymer · doi:10.1016/j.polymer.2004.10.009 · Cited by 436
Self-citationXie, F., Halley, P. J., & Avérous, L. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.07.002 · Cited by 301
Deng, Y., Yu, C., Wongwiwattana, P., & Thomas, N. L. (2018) · Journal of Polymers and the Environment · doi:10.1007/s10924-018-1256-x · Cited by 193
“To transform the rotor speed of the Haake mixer to shear strain rate, the Newtonian equivalent expression [30], shown in Eq.”
MethodJalali Dil, E., Carreau, P. J., & Favis, B. D. (2015) · Polymer · doi:10.1016/j.polymer.2015.05.012 · Cited by 158
Metadata
- Authors
- Bousmina, M., Ait-Kadi, A., & Faisant, J. B.
- Venue
- Journal of Rheology
- Publisher
- Society of Rheology
- Published
- 1999-03-01
- Volume
- 43
- Issue
- 2
- Pages
- 415-433
- ISSN
- 0097-0360 (ISSN-L)
- 0148-6055
- 1520-8516
- OpenAlex
- W2045591372
- Cited by
- 316
- References
- 4
- FWCI
- 6.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of shear rate and viscosity from batch mixer data. https://app.cochat.ai/papers/10.1122/1.551044
- The paper
- Bousmina, M., Ait-Kadi, A., & Faisant, J. B. (1999). Determination of shear rate and viscosity from batch mixer data. Journal of Rheology. https://doi.org/10.1122/1.551044
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.