Estimate of the Optimum Cutoff Frequency for the Butterworth Low-Pass Digital Filter
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The purposes of this study were (a) to develop a procedure for objectively determining the optimum cutoff frequency for the Butterworth low-pass digital filler, and (b) to evaluate the cutoff frequencies derived from the residual analysis. A set of knee flexion-extension angle data in normal gait was used as the standard data set. The standard data were sampled at different sampling frequencies. Random errors with different magnitudes were added to the standard data to create different sets of raw data with a given sampling frequency. Each raw data set was filtered through a Butterworth low-pass digital filter at different cutoff frequencies. The cutoff frequency corresponding to the minimum error in the second time derivatives for a given set of raw data was considered as the optimum for that set of raw data. A procedure for estimating the optimum cutoff frequency from the sampling frequency and estimated relative mean error in the raw data set was developed. The estimated optimum cutoff frequency significantly correlated to the true optimum cutoff frequency with a correlation determinant value of 0.96. This procedure was applied to estimate the optimum cutoff frequency for another set of kinematic data. The calculated accelerations of the filtered data essentially matched the measured acceleration curve. There is no correlation between the cutoff frequency derived from the residual analysis and the true optimum cutoff frequency. The cutoff frequencies derived from the residual analysis were significantly lower than the optimum, especially when the sampling frequency is high.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Normative data of knee joint motion and ground reaction forces in adult level walking
Chao, E. Y., Laughman, R. K., Schneider, E., & Stauffer, R. N. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90129-x · Cited by 366
DATA SMOOTHING AND DIFFERENTIATION PROCEDURES IN BIOMECHANICS
Wood, G. A. (1982) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-198201000-00010 · Cited by 172
Cited by
A Comparison of Knee Kinetics between Male and Female Recreational Athletes in Stop-Jump Tasks
Chappell, J. D., Yu, B., Kirkendall, D. T., & Garrett, W. E. (2002) · The American Journal of Sports Medicine · doi:10.1177/03635465020300021901 · Cited by 561
Self-citationLower extremity biomechanics during the landing of a stop-jump task
Yu, B., Lin, C.-F., & Garrett, W. E. (2006) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.11.003 · Cited by 471
Self-citationEffect of Fatigue on Knee Kinetics and Kinematics in Stop-Jump Tasks
Chappell, J. D., Herman, D. C., Knight, B. S., Kirkendall, D. T., Garrett, W. E., & Yu, B. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546504273047 · Cited by 405
Self-citationChappell, J. D., Creighton, R. A., Giuliani, C., Yu, B., & Garrett, W. E. (2007) · The American Journal of Sports Medicine · doi:10.1177/0363546506294077 · Cited by 368
Self-citationThe Role of Rate of Force Development on Vertical Jump Performance
McLellan, C. P., Lovell, D. I., & Gass, G. C. (2011) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181be305c · Cited by 342
Lephart, S. M., Abt, J. P., Ferris, C. M., Sell, T. C., Nagai, T., Myers, J. B., & Irrgang, J. J. (2005) · British Journal of Sports Medicine · doi:10.1136/bjsm.2005.019083 · Cited by 264
Brown, C., Padua, D., Marshall, S. W., & Guskiewicz, K. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.02.013 · Cited by 231
Oñate, J. A., Guskiewicz, K. M., Marshall, S. W., Giuliani, C., Yu, B., & Garrett, W. E. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546504271499 · Cited by 221
“The 3-D coordinates of the reflective markers were filtered through a low-pass Butterworth digital filter at estimated optimum cutoff frequencies.(33) An embedded right-hand Cartesian coordinate system was defined for each lower extremity segment to describe the position and orientation of the segment.”
MethodSelf-citationHerman, D. C., Weinhold, P. S., Guskiewicz, K. M., Garrett, W. E., Yu, B., & Padua, D. A. (2008) · The American Journal of Sports Medicine · doi:10.1177/0363546507311602 · Cited by 185
“Raw 3-dimensional coordinates were filtered through a low-pass Butterworth digital filter with an estimated optimum cutoff frequency.(55) The 3-dimensional local coordinates of the medial and lateral femoral condyles and medial malleolus were estimated from the 3-dimensional coordinates of markers on the tibia in the…”
MethodSelf-citationMacrum, E., Bell, D. R., Boling, M., Lewek, M., & Padua, D. (2012) · Journal of Sport Rehabilitation · doi:10.1123/jsr.21.2.144 · Cited by 180
Multi-Modal Remote Sensing Image Matching Considering Co-Occurrence Filter
Yao, Y., Zhang, Y., Wan, Y., Liu, X., Yan, X., & Li, J. (2022) · IEEE Transactions on Image Processing · doi:10.1109/tip.2022.3157450 · Cited by 179
Effect of rotator cuff pathology on shoulder rhythm
Mell, A. G., LaScalza, S., Guffey, P., Ray, J., Maciejewski, M., Carpenter, J. E., & Hughes, R. E. (2005) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2004.09.018 · Cited by 173
The Effects of Feedback with and without Strength Training on Lower Extremity Biomechanics
Herman, D. C., Oñate, J. A., Weinhold, P. S., Guskiewicz, K. M., Garrett, W. E., Yu, B., & Padua, D. A. (2009) · The American Journal of Sports Medicine · doi:10.1177/0363546509332253 · Cited by 159
Self-citationInfluence of Averaging Method on Muscle Deoxygenation Interpretation during Repeated-Sprint Exercise
Rodriguez, R. F., Townsend, N. E., Aughey, R. J., & Billaut, F. (2018) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.13238 · Cited by 47
Zhao, S., Lindinger, S., Ohtonen, O., & Linnamo, V. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.948919 · Cited by 4
Metadata
- Authors
- Yu, B., Gabriel, D., Noble, L., & An, K.-N.
- Venue
- Journal of Applied Biomechanics
- Publisher
- Human Kinetics
- Published
- 1999-08
- Volume
- 15
- Issue
- 3
- Pages
- 318-329
- ISSN
- 1065-8483 (ISSN-L)
- 1543-2688
- OpenAlex
- W2171718210
- Cited by
- 355
- References
- 2
- FWCI
- 1.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.