Cited by 62Physical Activity and HealthContext-Aware Activity Recognition SystemsBalance, Gait, and Falls Prevention

Validity of 2 Devices for Measuring Steps Taken by Older Adults in Assisted-Living Facilities

Bergman, Randall J., Bassett, David R., Klein, Diane A.·2008·Journal of Physical Activity and Health

Abstract

Background: This 2-part study examined validity of selected motion sensors for assessing physical activity in older adults residing in assisted-living communities. Methods: Twenty-one older adults (mean age = 78.6 ± 13.1 years) wore the StepWatch 3 Step Activity Monitor (SW3) and the Yamax Digi-Walker SW-200 pedometer (DW). Part I compared accuracy of these devices for measuring steps taken over 161 m. Part II compared devices over a 1-day (24-hour) period. Results: In part I, the DW recorded 51.9% (r2 = –.08, P = .75) and the SW3 recorded 102.6% (r2 = .99, P < .001) of steps. In part II, the DW measured significantly fewer steps (1587 ± 1057 steps) than did the SW3 (6420 ± 3180 steps). Conclusions: The SW3 pedometer was more accurate in counting steps and recorded higher 24-hour step counts than the DW pedometer. Thus, the SW3 is a valid research instrument for monitoring activity in the assisted-living population.

Integrity signals

Registry

Crossref · 10.1123/jpah.5.s1.s166

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Most waist-mounted pedometers are very accurate at speeds of 3.0 mph and above, but accuracy declines at slower speeds; at 2.0 mph they may capture 75% of steps, and at 1.0 mph they hardly register steps.

    “Studies have demonstrated that most waist-mounted pedometers are very accurate at speeds of 3.0 mph (80.4 m/min) and above, but their accuracy declines at slower speeds. At 2.0 mph (54 m/min) they may capture 75% of steps, and at 1.0 mph they hardly register steps at all.”
  • Waist-mounted pedometers are notoriously inaccurate in older adults in assisted-care settings who walk with a slow, shuffling gait.

    “Thus, waist-mounted pedometers are notoriously inaccurate in older adults in assisted-care settings, who walk with a slow, shuffling gait [17].”
  • The main sources of error for waist-worn spring-levered pedometers are slow walking speeds and obesity, both causing underestimation of steps.

    “The main sources of error for this class of devices are slow walking speeds and obesity, which both result in underestimation of steps.”

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 19 · Cited by 62

Authors
Bergman, R. J., Bassett, D. R., & Klein, D. A.
Affiliations
Kentucky Wesleyan College (US)
Venue
Journal of Physical Activity and Health
Published
2008-01
Volume
5
Issue
s1
Pages
S166-S175
ISSN
  • 1543-3080 (ISSN-L)
  • 1543-5474
OpenAlex
W2133152359
Cited by
62
References
19
Citations by year
2024: 2 · 2023: 1 · 2022: 1 · 2021: 1 · 2019: 2 · 2018: 5 · 2017: 4 · 2016: 5 · 2015: 5 · 2014: 5 · 2013: 6 · 2012: 6
FWCI
4.29
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Physical Activity and Health (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Physical Activity and Health
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
Keywords
pedometers, step count accuracy, physical activity measurement, older adults, assisted living, device validity
MeSH terms
Aged, Aged, 80 and over, Data Collection, Female, Humans, Male, Nursing Homes, Reproducibility of Results, Walking, Monitoring, Ambulatory, Assisted Living Facilities

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review