Actigraph Calibration in Obese/Overweight and Type 2 Diabetes Mellitus Middle-Aged to Old Adult Patients
Open accessThe DOI matches its Crossref record.
Abstract
Background: Several methods exist to asses and control physical intensity levels of subjects engaged in physical activities programs, accelerometry is a method that could be easily used in the field. The purposes were: to calibrate Actigraph in middle-aged to old obese/overweight and DM2 adult patients; and to determine the threshold counts for sedentary, light, moderate, and vigorous physical activity (PA). Methods: Sample comprise 26 participants (62.6 ± 6.5 years of age) of both gender. Counts and VO2 were simultaneously assessed during: resting, seating, standing, walking at 2.5 km·h−1, 5 km·h−1, and 6 km·h−1. A hierarchical linear model was used to derive a regression equation between MET and counts. Receiver operating characteristics (ROC) analysis was used to define thresholds for PA levels. Results: The regression equation was: MET = 1.388400490262 + 0.001312683420044 (counts·min−1), r = .867. The threshold counts for sedentary-light, light-moderate and moderate-vigorous PA were: 200, 1240, 2400 counts·min−1 respectively. Conclusion: The Actigraph is a valid and useful device for the assessment of the amount of time spent in each PA intensity levels in obese/overweight and DM2 middle-aged to old adult patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tudor-Locke, C., Brashear, M. M., Johnson, W. D., & Katzmarzyk, P. T. (2010) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-7-60 · Cited by 375
Evenson, K., Buchner, D., & Morland, K. (2011) · Preventing Chronic Disease · doi:10.5888/pcd9.110109 · Cited by 267
Do Activity Levels Increase After Total Hip and Knee Arthroplasty?
Harding, P., Holland, A. E., Delany, C., & Hinman, R. S. (2014) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-013-3427-3 · Cited by 220
“Activity cut points have been calibrated using the ActiGraph accelerometer in middle-aged to old obese/overweight and Type 2 diabetes mellitus adult patients [28].”
BackgroundMethodOzemek, C., Cochran, H. L., Strath, S. J., Byun, W., & Kaminsky, L. A. (2013) · BMC Medical Research Methodology · doi:10.1186/1471-2288-13-53 · Cited by 69
“In addition to creating absolute cutpoints relative to one’s age, Lopes and colleagues determined absolute cutpoints specifically for overweight and obese individuals with type 2 diabetes [33].”
BackgroundZisko, N., Carlsen, T., Salvesen, Ø., Aspvik, N. P., Ingebrigtsen, J. E., Wisløff, U., & Stensvold, D. (2015) · BMC Geriatrics · doi:10.1186/s12877-015-0093-1 · Cited by 32
“overweight, obese, type 2 diabetes) [24, 25].”
Comparison of wrist-worn and hip-worn activity monitors under free living conditions
Hargens, T. A., Deyarmin, K. N., Snyder, K. M., Mihalik, A. G., & Sharpe, L. E. (2017) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2016.1271046 · Cited by 30
Metadata
- Authors
- Lopes, V. P., Magalhães, P., Bragada, J., & Vasques, C.
- Venue
- Journal of Physical Activity and Health
- Publisher
- Human Kinetics
- Published
- 2009-01
- Volume
- 6
- Issue
- s1
- Pages
- S133-S140
- ISSN
- 1543-3080 (ISSN-L)
- 1543-5474
- OpenAlex
- W24495949
- Cited by
- 68
- References
- 0
- FWCI
- 1.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.