Computational multiheterodyne spectroscopy
Open accessAbstract
A computationally enabled approach is used to perform dual-comb spectroscopy without a phase reference.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Recording n∆f_r signal can improve the jitter tracking speed, as reported in dual-comb spectroscopy.
“Recording 𝑛∆𝑓 r signal can improve the speed, as reported in dual-comb spectroscopy [38,39].”
From Jitter correction for asynchronous optical sampling terahertz spectroscopy using free-running pulsed lasers (2023) · cites this paper as [39]
The Results section describes continuously updating estimates of the offset and repetition rates, making the method amenable to real-time processing. The Results and Phase and timing correction sections also model comb-line signals with an n-dependent phase, but neither says that recording an nΔfᵣ signal improves jitter-tracking speed. Searches for higher-harmonic recording and faster tracking found no such comparison in our copy. (LLM, conf=0.71)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Coddington, I., Newbury, N., & Swann, W. (2016) · Optica · doi:10.1364/optica.3.000414 · Cited by 1,754 · see citing works
Coherent dual-comb spectroscopy at high signal-to-noise ratio
Coddington, I., Swann, W., & Newbury, N. (2010) · Physical Review A · doi:10.1103/physreva.82.043817 · Cited by 322 · see citing works
Flagged first, then by citations
Research works printed but not linked: 27
- [1]Udem T., Holzwarth R., Hänsch T. W., Optical frequency metrology. Nature 416, 233– 237 (2002). 11894107
- [2]van der Weide D. W., Keilmann F., Picosecond dual-source interferometer extending Fourier-transform spectrometer to microwave regime. IEEE MTT-S Int. Microwave Symp. Dig. 3, 1731– 1734 (1996).
- [3]D. W. van der Weide, F. Keilmann, U.S. Patent 5,748,309 (1998).
- [4]van der Weide D. W., Murakowski J., Keilmann F., Gas-absorption spectroscopy with electronic terahertz techniques. IEEE Trans. Microwave Theory Tech. 48, 740– 743 (2000).
- [5]Schiller S., Spectrometry with frequency combs. Opt. Lett. 27, 766– 768 (2002). 18007926
- [6]Diddams S. A., Hollberg L., Mbele V., Molecular fingerprinting with the resolved modes of a femtosecond laser frequency comb. Nature 445, 627– 630 (2007). 17287805
- [7]Coddington I., Swann W. C., Newbury N. R., Coherent multiheterodyne spectroscopy using stabilized optical frequency combs. Phys. Rev. Lett. 100, 013902 (2008). 18232764
- [10]Holzwarth R., Holzwarth R., Udem T., Hänsch T. W., Knight J. C., Wadsworth W. J., Russell P. S. J., Optical frequency synthesizer for precision spectroscopy. Phys. Rev. Lett. 85, 2264– 2267 (2000). 10977987
- [11]Roy J., Deschênes J.-D., Potvin S., Genest J., Continuous real-time correction and averaging for frequency comb interferometry. Opt. Express 20, 21932– 21939 (2012). 23037343
- [12]Ideguchi T., Poisson A., Guelachvili G., Picqué N., Hänsch T. W., Adaptive real-time dual-comb spectroscopy. Nat. Commun. 5, 3375 (2014). 24572636 PMC3948060
- [13]Deschênes J.-D., Giaccarri P., Genest J., Optical referencing technique with CW lasers as intermediate oscillators for continuous full delay range frequency comb interferometry. Opt. Express 18, 23358– 23370 (2010). 21164677
- [14]Giaccari P., Deschênes J.-D., Saucier P., Genest J., Tremblay P., Active Fourier transform spectroscopy combining the direct RF beating of two fiber-based mode-locked lasers with a novel referencing method. Opt. Express 16, 4347– 4365 (2008). 18542532
- [15]Del’Haye P., Schliesser A., Arcizet O., Wilken T., Holzwarth R., Kippenberg T. J., Optical frequency comb generation from a monolithic microresonator. Nature 450, 1214– 1217 (2007). 18097405
- [16]Kippenberg T. J., Holzwarth R., Diddams S. A., Microresonator-based optical frequency combs. Science 332, 555– 559 (2011). 21527707
- [17]Hugi A., Villares G., Blaser S., Liu H. C., Faist J., Mid-infrared frequency comb based on a quantum cascade laser. Nature 492, 229– 233 (2012). 23235876
- [18]Lu Q. Y., Razeghi M., Slivken S., Bandyopadhyay N., Bai Y., Zhou W. J., Chen M., Heydari D., Haddadi A., McClintock R., Amanti M., Sirtori C., High power frequency comb based on mid-infrared quantum cascade laser at λ ~ 9 μm. Appl. Phys. Lett. 106, 051105 (2015).
- [20]Wienold M., Röben B., Schrottke L., Grahn H. T., Evidence for frequency comb emission from a Fabry-Pérot terahertz quantum-cascade laser. Opt. Express 22, 30410– 30424 (2014). 25606987
- [22]Wang Y., Soskind M. G., Wang W., Wysocki G., High-resolution multi-heterodyne spectroscopy based on Fabry-Perot quantum cascade lasers. Appl. Phys. Lett. 104, 031114 (2014).
- [23]Villares G., Hugi A., Blaser S., Faist J., Dual-comb spectroscopy based on quantum cascade laser frequency combs. Nat. Commun. 5, 5192 (2014). 25307936
- [25]Suh M.-G., Yang Q.-F., Yang K. Y., Yi X., Vahala K., Microresonator soliton dual-comb spectroscopy. Optics (2016); http://arxiv.org/abs/1607.08222. 27738017 · arXiv
- [29]Villares G., Wolf J., Kazakov D., Süess M. J., Hugi A., Beck M., Faist J., On-chip dual-comb based on quantum cascade laser frequency combs. Appl. Phys. Lett. 107, 251104 (2015).
- [30]Burghoff D., Yang Y., Hayton D. J., Gao J.-R., Reno J. L., Hu Q., Evaluating the coherence and time-domain profile of quantum cascade laser frequency combs. Opt. Express 23, 1190– 1202 (2015). 25835878
- [34]Newbury N. R., Coddington I., Swann W., Sensitivity of coherent dual-comb spectroscopy. Opt. Express 18, 7929– 7945 (2010). 20588636
- [35]Wan E. A., Van Der Merwe R., The unscented Kalman filter for nonlinear estimation. Adapt. Syst. Signal Process. Commun. Control Symp. 2000. AS-SPCC. IEEE 2000 153– 158 (2002).
- [36]Christiansen G. S., Modeling of PRML timing loop as a Kalman filter. 1994 IEEE GLOBECOM. Commun. Glob. Bridg. 2, 1157– 1161 (1994).
- [37]Arulampalam M. S., Maskell S., Gordon N., Clapp T., A tutorial on particle filters for online nonlinear/non-Gaussian Bayesian tracking. IEEE Trans. Signal Process. 50, 174– 188 (2002).
- [39]Poore A. B., Slocumb B. J., Suchomel B. J., Obermeyer F. H., Herman S. M., Gadaleta S. M., Batch maximum likelihood (ML) and maximum a posteriori (MAP) estimation with process noise for tracking applications. Proc. SPIE 5204, 188– 199 (2004).
Cited by
Sorted by citations
A phase-stable dual-comb interferometer
Chen, Z., Yan, M., Hänsch, T. W., & Picqué, N. (2018) · Nature Communications · doi:10.1038/s41467-018-05509-6 · Cited by 139 · see citing works
Nakagawa, M., Kanda, N., Otsu, T., Ito, I., Kobayashi, Y., & Matsunaga, R. (2023) · Optics Express · doi:10.1364/oe.488866 · Cited by 3 · see citing works
- Authors
- Burghoff, D., Yang, Y., & Hu, Q.
- Affiliations
- Massachusetts Institute of Technology (US)
- Corresponding author
- Burghoff, David
- Yang, Yang
- Venue
- Science Advances
- Published
- 2016-11-04
- Volume
- 2
- Issue
- 11
- Pages
- e1601227-e1601227
- ISSN
- 2375-2548 (ISSN-L)
- PMC
- PMC5106200
- OpenAlex
- W2417056832
- Cited by
- 114
- References
- 2
- Citations by year
- 2026: 4 · 2025: 14 · 2024: 11 · 2023: 8 · 2022: 8 · 2021: 14 · 2020: 17 · 2019: 14 · 2018: 14 · 2017: 10
- FWCI
- 5.99
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc
- Locations
- Science Advances (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc)
- arXiv (Cornell University)
- Funders
- Defense Sciences Office, DARPA (ID0EB1AG11603, W31P4Q- 16-1-0001)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Fiber Laser Technologies
- Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Keywords
- dual-comb spectroscopy, frequency combs, phase noise, coherent integration, phase reference, high-resolution spectroscopy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review