The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Coherent Soft X-ray Generation in the Water Window with Quasi-Phase Matching
Abstract
We demonstrate enhanced generation of coherent light in the “water window” region of the soft x-ray spectrum at 4.4 nanometers, using quasi–phase-matched frequency conversion of ultrafast laser pulses. By periodically modulating the diameter of a gas-filled hollow waveguide, the phase mismatch normally present between the laser light and the generated soft x-ray light can be partially compensated. This makes it possible to use neon gas as the nonlinear medium to coherently convert light up to the water window, illustrating that techniques of nonlinear optics can be applied effectively in the soft x-ray region of the spectrum. These results advance the prospects for compact coherent soft x-ray sources for applications in biomicroscopy and in chemical spectroscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Temporal phase control of soft-x-ray harmonic emission
Chang, Z., Rundquist, A., Wang, H., Christov, I., Kapteyn, H. C., & Murnane, M. M. (1998) · Physical Review A · doi:10.1103/physreva.58.r30 · Cited by 181
Self-citation
Cited by
Krausz, F., & Ivanov, M. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.163 · Cited by 5,468
Soft X-ray microscopy at a spatial resolution better than 15 nm
Chao, W., Harteneck, B. D., Liddle, J. A., Anderson, E. H., & Attwood, D. T. (2005) · Nature · doi:10.1038/nature03719 · Cited by 851
Self-citationPhase matching of high harmonic generation in the soft and hard X-ray regions of the spectrum
Popmintchev, T., Chen, M.-C., Bahabad, A., Gerrity, M., Sidorenko, P., Cohen, O., Christov, I. P., Murnane, M. M., & Kapteyn, H. C. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903748106 · Cited by 419
Self-citationMacroscopic aspects of attosecond pulse generation
Gaarde, M. B., Tate, J. L., & Schafer, K. J. (2008) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/41/13/132001 · Cited by 398
Colloquium: Optimal control of high-harmonic generation
Winterfeldt, C., Spielmann, C., & Gerber, G. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.117 · Cited by 384
Metadata
- Authors
- Gibson, E. A., Paul, A., Wagner, N., Tobey, R., Gaudiosi, D., Backus, S., Christov, I. P., Aquila, A., Gullikson, E. M., Attwood, D. T., Murnane, M. M., & Kapteyn, H. C.
- Venue
- Science
- Published
- 2003-10-03
- Volume
- 302
- Issue
- 5642
- Pages
- 95-98
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2164753763
- Cited by
- 372
- References
- 1
- FWCI
- 22.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coherent Soft X-ray Generation in the Water Window with Quasi-Phase Matching. https://app.cochat.ai/papers/10.1126/science.1088654
- The paper
- Gibson, E. A., Paul, A., Wagner, N., Tobey, R., Gaudiosi, D., Backus, S., Christov, I. P., Aquila, A., Gullikson, E. M., Attwood, D. T., Murnane, M. M., & Kapteyn, H. C. (2003). Coherent Soft X-ray Generation in the Water Window with Quasi-Phase Matching. Science. https://doi.org/10.1126/science.1088654
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.