The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
High-Performance Solid Acid Fuel Cells Through Humidity Stabilization
Abstract
Although they hold the promise of clean energy, state-of-the-art fuel cells based on polymer electrolyte membrane fuel cells are inoperable above 100°C, require cumbersome humidification systems, and suffer from fuel permeation. These difficulties all arise from the hydrated nature of the electrolyte. In contrast, “solid acids” exhibit anhydrous proton transport and high-temperature stability. We demonstrate continuous, stable power generation for both H 2 /O 2 and direct methanol fuel cells operated at ∼250°C using a humidity-stabilized solid acid CsH 2 PO 4 electrolyte.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solid acids as fuel cell electrolytes
Haile, S. M., Boysen, D. A., Chisholm, C. R. I., & Merle, R. B. (2001) · Nature · doi:10.1038/35073536 · Cited by 892
Self-citationInstability of Sulfate and Selenate Solid Acids in Fuel Cell Environments
Merle, R. B., Chisholm, C. R. I., Boysen, D. A., & Haile, S. M. (2002) · Energy & Fuels · doi:10.1021/ef0201174 · Cited by 67
Self-citation
Cited by
Kreuer, K.-D., Paddison, S. J., Spohr, E., & Schuster, M. (2004) · Chemical Reviews · doi:10.1021/cr020715f · Cited by 2,187
Recent Advances and Challenges of Electrocatalytic N2Reduction to Ammonia
Qing, G., Ghazfar, R., Jackowski, S. T., Habibzadeh, F., Ashtiani, M. M., Chen, C.-P., Smith, M. R., & Hamann, T. W. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00659 · Cited by 1,323
Towards establishing standard performance metrics for batteries, supercapacitors and beyond
Noori, A., El-Kady, M. F., Rahmanifar, M. S., Kaner, R. B., & Mousavi, M. F. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00581h · Cited by 1,303
Aliphatic/Aromatic Polyimide Ionomers as a Proton Conductive Membrane for Fuel Cell Applications
Asano, N., Aoki, M., Suzuki, S., Miyatake, K., Uchida, H., & Watanabe, M. (2006) · Journal of the American Chemical Society · doi:10.1021/ja0571491 · Cited by 657
The mechanism of proton conduction in phosphoric acid
Vilčiauskas, L., Tuckerman, M. E., Bester, G., Paddison, S. J., & Kreuer, K.-D. (2012) · Nature Chemistry · doi:10.1038/nchem.1329 · Cited by 586
A Carbon Material as a Strong Protonic Acid
Hara, M., Yoshida, T., Takagaki, A., Takata, T., Kondo, J. N., Hayashi, S., & Domen, K. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200453947 · Cited by 579
Marx, D., Chandra, A., & Tuckerman, M. E. (2010) · Chemical Reviews · doi:10.1021/cr900233f · Cited by 522
Ion Conducting Membranes for Fuel Cells and other Electrochemical Devices
Kreuer, K.-D. (2014) · Chemistry of Materials · doi:10.1021/cm402742u · Cited by 467
Nonhumidified Intermediate Temperature Fuel Cells Using Protic Ionic Liquids
Lee, S.-Y., Ogawa, A., Kanno, M., Nakamoto, H., Yasuda, T., & Watanabe, M. (2010) · Journal of the American Chemical Society · doi:10.1021/ja102367x · Cited by 465
Solid acid proton conductors: from laboratory curiosities to fuel cell electrolytes
Haile, S. M., Chisholm, C. R. I., Sasaki, K., Boysen, D. A., & Uda, T. (2007) · Faraday Discuss. · doi:10.1039/b604311a · Cited by 318
Self-citationSolid acid membranes for high temperature (¿140° C) proton exchange membrane fuel cells
Hogarth, W. H. J., Diniz da Costa, J. C., & Lu, G. Q. (. (2005) · Journal of Power Sources · doi:10.1016/j.jpowsour.2004.11.020 · Cited by 288
Metadata
- Authors
- Boysen, D. A., Uda, T., Chisholm, C. R. I., & Haile, S. M.
- Venue
- Science
- Published
- 2004-01-02
- Volume
- 303
- Issue
- 5654
- Pages
- 68-70
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2007387941
- Cited by
- 486
- References
- 2
- FWCI
- 11.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.