The DOI matches its Crossref record.
Atom Interferometer Measurement of the Newtonian Constant of Gravity
Abstract
We measured the Newtonian constant of gravity, G , using a gravity gradiometer based on atom interferometry. The gradiometer measures the differential acceleration of two samples of laser-cooled Cs atoms. The change in gravitational field along one dimension is measured when a well-characterized Pb mass is displaced. Here, we report a value of G = 6.693 × 10 –11 cubic meters per kilogram second squared, with a standard error of the mean of ±0.027 × 10 –11 and a systematic error of ±0.021 × 10 –11 cubic meters per kilogram second squared. The possibility that unknown systematic errors still exist in traditional measurements makes it important to measure G with independent methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Atom interferometry with up to 24-photon-momentum-transfer beam splitters
Müller, H., Chiow, S.-W., Long, Q., Herrmann, S., & Chu, S. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.180405 · Cited by 290
Precision measurement of the Newtonian gravitational constant
Xue, C., Liu, J.-P., Li, Q., Wu, J.-F., Yang, S.-Q., Liu, Q., Shao, C.-G., Tu, L.-C., Hu, Z.-K., & Luo, J. (2020) · National Science Review · doi:10.1093/nsr/nwaa165 · Cited by 60
Precision bounds for gradient magnetometry with atomic ensembles
Apellaniz, I., Urizar-Lanz, I., Zimborás, Z., Hyllus, P., & Tóth, G. (2018) · Physical Review A · doi:10.1103/physreva.97.053603 · Cited by 45
Metadata
- Authors
- Fixler, J. B., Foster, G. T., McGuirk, J. M., & Kasevich, M. A.
- Venue
- Science
- Published
- 2007-01-05
- Volume
- 315
- Issue
- 5808
- Pages
- 74-77
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2009012440
- Cited by
- 554
- References
- 0
- FWCI
- 28.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Atom Interferometer Measurement of the Newtonian Constant of Gravity. https://app.cochat.ai/papers/10.1126/science.1135459
- The paper
- Fixler, J. B., Foster, G. T., McGuirk, J. M., & Kasevich, M. A. (2007). Atom Interferometer Measurement of the Newtonian Constant of Gravity. Science. https://doi.org/10.1126/science.1135459
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.