Muscular Thin Films for Building Actuators and Powering Devices
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
We demonstrate the assembly of biohybrid materials from engineered tissues and synthetic polymer thin films. The constructs were built by culturing neonatal rat ventricular cardiomyocytes on polydimethylsiloxane thin films micropatterned with extracellular matrix proteins to promote spatially ordered, two-dimensional myogenesis. The constructs, termed muscular thin films, adopted functional, three-dimensional conformations when released from a thermally sensitive polymer substrate and were designed to perform biomimetic tasks by varying tissue architecture, thin-film shape, and electrical-pacing protocol. These centimeter-scale constructs perform functions as diverse as gripping, pumping, walking, and swimming with fine spatial and temporal control and generating specific forces as high as 4 millinewtons per square millimeter.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Hydrogels are attractive materials for tissue engineering, but efforts to date have shown limited ability to produce the microstructural features necessary to promote cellular self-organization into hierarchical 3D organ models.”
From Fibre-infused gel scaffolds guide cardiomyocyte alignment in 3D-printed ventricles (2023) · cites this paper as [9]
In the citing paper
“These methods are however limited in their ability to produce tissues on complex geometries that fully replicate cardiac function.”
From Fibre-infused gel scaffolds guide cardiomyocyte alignment in 3D-printed ventricles (2023) · cites this paper as [9]
In the citing paper
“and is based on previously published methods9”
From Fibre-infused gel scaffolds guide cardiomyocyte alignment in 3D-printed ventricles (2023) · cites this paper as [9]
Citations
Cites
Cardiac excitation–contraction coupling
Bers, D. M. (2002) · Nature · doi:10.1038/415198a · Cited by 4,744
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Self-citationExcitation-Contraction Coupling and Cardiac Contractile Force
Bers, D. M., & Zhu, Y. (2010) · Journal of Cardiovascular Disease Research · doi:10.1016/s0975-3583(10)11011-0 · Cited by 1,603
Excitation-Contraction Coupling and Cardiac Contractile Force
Bers, D. M. (2001) · Developments in Cardiovascular Medicine · doi:10.1007/978-94-010-0658-3 · Cited by 1,548
Artificial Muscle Technology: Physical Principles and Naval Prospects
Madden, J. D. W., Vandesteeg, N. A., Anquetil, P. A., Madden, P. G. A., Takshi, A., Pytel, R. Z., Lafontaine, S. R., Wieringa, P. A., & Hunter, I. W. (2004) · IEEE Journal of Oceanic Engineering · doi:10.1109/joe.2004.833135 · Cited by 1,035
Engineered heart tissue grafts improve systolic and diastolic function in infarcted rat hearts
Zimmermann, W.-H., Melnychenko, I., Wasmeier, G., Didié, M., Naito, H., Nixdorff, U., Hess, A., Budinsky, L., Brune, K., Michaelis, B., et al. (2006) · Nature Medicine · doi:10.1038/nm1394 · Cited by 993
Shaping of Elastic Sheets by Prescription of Non-Euclidean Metrics
Klein, Y., Efrati, E., & Sharon, E. (2007) · Science · doi:10.1126/science.1135994 · Cited by 642
Locomotor repertoire of the larval zebrafish: swimming, turning and prey capture
Budick, S. A., & O’Malley, D. M. (2000) · Journal of Experimental Biology · doi:10.1242/jeb.203.17.2565 · Cited by 499
Fashioning the vertebrate heart: earliest embryonic decisions
Fishman, M. C., & Chien, K. R. (1997) · Development · doi:10.1242/dev.124.11.2099 · Cited by 491
Self-assembled microdevices driven by muscle
Xi, J., Schmidt, J. J., & Montemagno, C. D. (2005) · Nature Materials · doi:10.1038/nmat1308 · Cited by 322
Research works printed but not linked: 2
- K. Baaret al., FASEB J.19, 275 (2005).
- N. Bursac, K. K. Parker, S. Iravanian, L. Tung, Circ. Res.91, E45 (2002).
Cited by
Items 701–757 of 757
for achievement of chemical robot
Nakamaru, S., Maeda, S., Hara, Y., & Hashimoto, S. (2009)
Long-Term Prospects for Arrhythmia Treatment: Advantages and Limitations of Gene and Cell Therapies
Rosen, M. R. (2011) · Humana Press eBooks · doi:10.1007/978-1-61779-021-8_20
“One thought has been to encapsulate hMSCs carrying pacemaker genes or to load them onto a biomaterial Long-Term Prospects for Arrhythmia Treatment: Advantages and Limitations 385 that will prevent their migration [ 44 ].”
BackgroundKamm, R. D., & Bashir, R. (2013) · PMC
Morimoto, Y., Mori, S., Sakai‐Takemura, F., & Takeuchi, S. (2016) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2016.7421612
Hoshino, T., & Morishima, K. (2008) · Journal of the Robotics Society of Japan · doi:10.7210/jrsj.26.651
Human Stem Cell‐Derived Cardiomyocyte In Vitro Models for Cardiotoxicity Screening
Walker, T. M., Harris, K. L., Maifoshie, E., & Chaudhary, K. W. (2016) · Wiley eBooks · doi:10.1002/9781119135449.ch6
Engineering Contractile 2D and 3D Human Skeletal and Cardiac Muscle Microtissues
Duffy, R. M. (2016) · KiltHub Repository · doi:10.1184/r1/6716261
MUSCLE ACTUATOR WITH TENDON-LIKE STRUCTURES
Morimoto, Y., Onoe, H., & Takeuchi, S. (2014) · International Conference on Miniaturized Systems for Chemistry and Life Sciences (MicroTAS)
Jang, J., & Cho, D. (2017) · Journal of Thoracic Disease · doi:10.21037/jtd.2017.02.33 · Cited by 1
Bio-Inspired Cell Sense-and-Respond Systems Through Bio-Synthetic and Robotics Approaches
Justus, K. (2017) · KiltHub Repository · doi:10.1184/r1/6714992
Wilson, K. A. (2009) · Journal of International Crisis and Risk Communication Research
3A1-X04 Microrobot that self-organizes by self-driving(Bio-Mimetics and Bio-Mechatronics)
Inoue, N., Shimizu, M., & Hosoda, K. (2014) · The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec) · doi:10.1299/jsmermd.2014._3a1-x04_1
Control of cardiomyocyte contraction for actuation of bio-syncretic robots
Zhang, C., Wang, W., Xi, N., Wang, Y., & Liu, L. (2017) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2017.7989574
Development of an Endothelial Cell Niche in Three-dimensional Hydrogels
Aizawa, Y. (2012) · TSpace (University of Toronto)
Yip, J. K., & McCain, M. L. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813671-3.00008-6 · Cited by 1
Microfabrication Approaches for Understanding the Role of Vascular Mechanics in Progressive Diseases
Hald, E. S. (2016) · University of Minnesota Digital Conservancy (University of Minnesota)
Papademetriou, I. T. (2018) · Springer eBooks · doi:10.1007/978-3-319-92946-0_17
Microfluidic Platforms for Biofabrication and 3D Tissue Modeling
Nie, M., & Takeuchi, S. (2019) · Royal Society of Chemistry eBooks · doi:10.1039/9781788012683-00049
Bio-mechanical Characterization of Adherent Cell Layers with a PDMS Cantilever
Holley, M. T. (2019) · Louisiana State University · doi:10.31390/gradschool_dissertations.5116
“Various biorobots were built using 2-dimensinal sheets of cardiomyocytes [60, 61, 63, 65, 79, 83, 84] while there are limited reports on 2-dimensional sheets of skeletal muscle cells.”
BackgroundMethodFabrication, Control, and Applications of Programmable Soft Electrothermal Actuators.
Cao, Y. (2020) · NCSU Libraries Repository (North Carolina State University Libraries)
Lücker, P. B. (2018) · TSpace (University of Toronto)
Morimoto, Y., & Takeuchi, S. (2021) · Journal of the Robotics Society of Japan · doi:10.7210/jrsj.39.310
AgNW-based functional polymer cantilever to improve maturity and contractility of cardiomyocytes
Jeung, M.-Y., Sim, Y.-R., Yun, H.-Y., Kim, D., & Lee, D. (2021) · Journal of Sensor Science and Technology · doi:10.46670/jsst.2021.30.3.185
Bances, L. P. (1943) · Festa D'Elig: Elx
Cellular models and therapeutic perspectives in hypertrophic cardiomyopathy
Yigit, G., & Wollnik, B. (2021) · Medizinische Genetik · doi:10.1515/medgen-2021-2094
“In vitro 3D cardiac models can substitute this structure either by usage of synthetic polymers as, e. g., polydimethylsiloxane (PDMS), natural polymers like collagen, fibrin, or gelatin, or decellularized heart tissue, e. g., from mice [51, 53, 54].”
BackgroundWang, P., Chang, J., & Zhang, L. (2019) · Wiley eBooks · doi:10.1002/9783527816354.ch1
Arcibal, I. G., Pisano, V., Fathi, A., Dehghani, F., Hwang, Y., Dokmeci, M. R., & Khademhosseini, A. (2014) · Lab on a Chip · doi:10.1039/c3lc90135a
(2007) · Nature Biotechnology · doi:10.1038/nbt1007-1117
Morgan, B. P. (2016) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.726873829.793525408
Faculty Opinions recommendation of A tissue-engineered scale model of the heart ventricle.
Radisic, M. (2018) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.733680169.793554004
Faculty Opinions recommendation of A tissue-engineered scale model of the heart ventricle.
Truskey, G. A. (2018) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.733680169.793549351
Ag/CNT-PDMS crack sensing for measuring contractility of cardiomyocytes
Wang, L., Xu, X., Dou, W., Chen, J., Su, W., Li, A., Xu, C., Liu, X., Xin, L., & Ru, C. (2022) · International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS) · doi:10.1109/marss55884.2022.9870457
“Micro-post array [5, 6], optical tracking of a flexible membrane [7], traction force microscopy [8, 9], microcantilever including atomic force microscopy [10-12], and cell-drum thin film [13] were used to measure the”
MethodDevelopment of High-Cell-Density Tissue Method for Compressed Modular Bioactuator
Nomura, T., Takeuchi, M., Kim, E., Huang, Q., Hasegawa, Y., & Fukuda, T. (2022) · Micromachines · doi:10.3390/mi13101725
Introduction of Smart Materials: The Art to Outrival Technology
Savio, C. M., & Sharma, I. (2023) · BENTHAM SCIENCE PUBLISHERS eBooks · doi:10.2174/9789815049756123010017
Biohybrid Soft Robot Composed of Cultured Tissue×Microdevices
Morimoto, Y. (2024) · The Journal of the Institute of Electrical Engineers of Japan · doi:10.1541/ieejjournal.144.144
Bilayered Biofabrication Unlocks the Potential of Skeletal Muscle for Biohybrid Soft RobotsPreprint
Balciunaite, A., Yaşa, Ö., Filippi, M., Michelis, M. Y., & Katzschmann, R. K. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.03.01.582738
Concept of Pneumatic Soft Robot: Suction-Driven Locomotion
Parlikar, S., Zielinska, T. T., & Gumowski, K. (2024) · Lecture notes in networks and systems · doi:10.1007/978-3-031-70722-3_18
Modelling Framework and Insights About a Novel Low-Velocity Segmented Linear Motor Design
Endo, T., Chen, Y., Nielsen, P. M. F., & Ruddy, B. P. (2024) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icem60801.2024.10700152
“We suggest that an electric motor structured in a similar manner may be able to replicate the wide range of stroke lengths, forces, actuation frequencies, and high energy densities associated with skeletal muscle [12].”
Background森本, 雄. (2024) · Journal of the Society of Biomechanisms · doi:10.3951/sobim.48.2_62
Engineered Living Materials II (NanoTrust-Dossier No65en - June 2025)
van Nieuwenhoven, R. W., Gisinger, F., Hageneder, L., & Gebeshuber, I. C. (2025) · doi:10.1553/ita-nt-065en · Cited by 3
Xiaoshuai, 刘. L., Mengna, 叶. Y., Yihao, 陈. C., Jiaxi, 郑. Z., Haifeng, 覃. Q., Guangyi, 杨. Y., Zheng, X., & Baojun, 李. L. (2025) · Acta Optica Sinica (Online) · doi:10.3788/aosol250470
Release, Transfer, Fold: Using a Silicone Adhesive for On-Demand 3D Tissue Engineering
Roth, D., Zampa, B., Augustin, R., Payandehjoo, D., Porcella, G., Şahin, A. T., van der Does, A. M., & Nawroth, J. C. (2025) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5c01130
Choi, Y., Son, Y. H., Kim, M. S., Park, S., & Lee, K. Y. (2025) · BioChip Journal · doi:10.1007/s13206-025-00245-8
“The micropatterned PDMS substrates were fabricated via microcontact printing using line-patterned PDMS stamps, as outlined in previous studies [39, 40 ].”
Defining the parameter space for construction of cardiac ventricle models
Okhovatian, S., & Radisic, M. (2025) · Biophysics Reviews · doi:10.1063/5.0272634
A Fast Bipedal Biohybrid Crawler Driven by Single Muscle Swinging
Gao, L., Wu, W., Chen, W., Liu, Z., Xie, X., Li, L., Lei, Q., Wan, Y., Feng, J., He, J., et al. (2026) · Soft Robotics · doi:10.1177/21695172261421859
“Our crawler outperformed existing locomotive biohybrid crawling robots actuated by cardiomyocytes, 12,31 – 33 insect dorsal vessel tissues, 27 and skeletal muscles 13 – 17, 19, 26, 34 , 35 in terms There are three main reasons for the crawler ’ s superior performance: powerful muscle tissue, new…”
Liao, A. S., Bennington, M. J., Dai, K., İrez, A. B., Sun, A., Schaffer, S., Chopra, B., Seok, J. M., Adams, R. A., Zhang, Y. J., et al. (2026) · Journal of Biomechanical Engineering · doi:10.1115/1.4071099
Stroke volume analog on a chip – in vitro hydrodynamic model of cardiac pumping efficiency
Zimmerman, J. F., MacQueen, L. A., Henze, D. E., Drennan, D. J., Kim, S. L., Ardoña, H. A. M., Choi, S., Jin, Q., & Parker, K. K. (2026) · Lab on a Chip · doi:10.1039/d5lc00547g
Self-citationMicro-comb 3D printing: rapid fabrication of tissue-guiding substrates using micro-embossed nozzles
Butdayev, S., Leone, S., Nikzad, S., Kajtez, J., Lauritzen, K. B., Sante, M. D., Pasqualini, F. S., Calløe, K., Marie, R., Keller, S. S., et al. (2026) · Biofabrication · doi:10.1088/1758-5090/ae5fd9
“For instance, patterns of ECM proteins capable of guiding cell spreading and extension, can be generated using light-based lithographic processes [12, 13] or soft lithography based on polydimethylsiloxane (PDMS) stamps [14, 15].”
Wu, A., Xin, Z., Dong, X., Zheng, Z., Cui, J., Fukuda, T., & Wang, H. (2026) · Advanced Functional Materials · doi:10.1002/adfm.76111
Son, Y. H., Sheng, C. Y., Jeong, J., Choi, Y., Jung, H., Won, J., Atinsky, A., Park, J., Kim, J., Lee, K. Y., et al. (2026) · BioChip Journal · doi:10.1007/s13206-026-00268-9
“For each recording, cantilever bending imaging data were acquired at a frame rate of 100 Hz over at least 5 s. Post-processing of the cantilever bending imaging data was conducted using custom software written in MATLAB (MathWorks) [41 , 42].”
Jang, Y., Shani, K., Clouvel, A., Prondzynski, M., Nuebling, S., Shin, C. J., Wang, Y., Ciucci, G., Kawai, M., Lee, Y. S., et al. (2026) · APL Bioengineering · doi:10.1063/5.0335477 · Cited by 1
“21,22 To enable a standardized comparison between 2D-Mono and 3D-EB hiPSC-CM differentiation, we applied a Wnt signaling-modulated protocol to hiPSCs maintained as a master cell bank (MCB), 18 which retained high pluripotency as indicated by greater than 90% SSEA4 positivity [Fig.”
Self-citationHeart-on-a-Chip: Theory, Evidence, and Personalised Medicine
Joshi, P., Zhang, Y. S., & Mokashi, S. (2026) · Heart Lung and Circulation · doi:10.1016/j.hlc.2026.03.060
Liu, K., Shanmugasundaram, A., Sun, H., Li, L., Jeong, G., Ko, S. Y., Kim, E., Lee, B., & Shanmugasundaram, A. (2026) · ACS Sensors · doi:10.1021/acssensors.6c01331
X-muscle actuator with selective regional contraction for a biohybrid rotatable joint
Yan, G., Liu, Z., Li, S., Li, S., Li, L., 迟常亮, & Gao, L. (2026) · Bio-Design and Manufacturing · doi:10.1631/bdm.2500617
From living actuators to architected machines: Biomimetic 3D and 4D printing for biohybrid robots
Hernandez, M. J. V., Rodríguez, A. D. J. A., Yang, Y., Zhang, L., Shin, S. R., 이지현, Govindaraj, K., Ha, C., & Wang, N. (2026) · Additive Manufacturing Frontiers · doi:10.1016/j.amf.2026.200407
Wireless bioelectronic control architectures for muscle-powered biohybrid robotic systems
Tetsuka, H., & Hirano, M. (2026) · APL Bioengineering · doi:10.1063/5.0339053
Pajouhande, M., Celikkin, N., Rafieyan, S., Tirelli, M. C., Maiullari, F., Piletskaya, M., & Costantini, M. (2026) · Gels · doi:10.3390/gels12100923
“Locomotion: yes—centimeter-scale muscularthinfilmsgripping, pumping,walkingandswimming[54].”
Influential
Metadata
- Authors
- Feinberg, A. W., Feigel, A., Shevkoplyas, S. S., Sheehy, S., Whitesides, G. M., & Parker, K. K.
- Affiliations
- Harvard University (US)
- Corresponding author
- Whitesides, George M.
- Parker, Kevin Kit
- Venue
- Science
- Published
- 2007-09-07
- Volume
- 317
- Issue
- 5843
- Pages
- 1366-1370
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2064019624
- Semantic Scholar
- 3070d01d2a66e9df550ce468a4e869c3f51fcfa9
- Cited by
- 765
- References
- 29
- Citations by year
- 2026: 22 · 2025: 33 · 2024: 31 · 2023: 30 · 2022: 36 · 2021: 45 · 2020: 39 · 2019: 43 · 2018: 51 · 2017: 43 · 2016: 50 · 2015: 38 · 2014: 53 · 2013: 57 · 2012: 47
- FWCI
- 32.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Keywords
- biohybrid actuators, cardiomyocytes, polydimethylsiloxane, myogenesis, biomimetic devices, electrical pacing, tissue structure, muscle force production, bio-inspired robotics
- MeSH terms
- Animals, Cells, Cultured, Dimethylpolysiloxanes, Microscopy, Fluorescence, Motion, Muscle Contraction, Myocardium, Robotics, Silicones, Anisotropy, Rats, Sprague-Dawley, Cell Culture Techniques, Tissue Engineering, Myocytes, Cardiac, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.