The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Atomic-Scale Chemical Imaging of Composition and Bonding by Aberration-Corrected Microscopy
Abstract
Using a fifth-order aberration-corrected scanning transmission electron microscope, which provides a factor of 100 increase in signal over an uncorrected instrument, we demonstrated two-dimensional elemental and valence-sensitive imaging at atomic resolution by means of electron energy-loss spectroscopy, with acquisition times of well under a minute (for a 4096-pixel image). Applying this method to the study of a La 0.7 Sr 0.3 MnO 3 /SrTiO 3 multilayer, we found an asymmetry between the chemical intermixing on the manganese-titanium and lanthanum-strontium sublattices. The measured changes in the titanium bonding as the local environment changed allowed us to distinguish chemical interdiffusion from imaging artifacts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electron Energy-Loss Spectroscopy in the Electron Microscope
Egerton, R. F. (1996) · Springer eBooks · doi:10.1007/978-1-4757-5099-7 · Cited by 1,640
Atomic-scale imaging of nanoengineered oxygen vacancy profiles in SrTiO3
Muller, D. A., Nakagawa, N., Ohtomo, A., Grazul, J. L., & Hwang, H. Y. (2004) · Nature · doi:10.1038/nature02756 · Cited by 691
Self-citationChen, J. G. (1997) · Surface Science Reports · doi:10.1016/s0167-5729(97)00011-3 · Cited by 620
Simultaneous STEM imaging and electron energy-loss spectroscopy with atomic-column sensitivity
Batson, P. E. (1993) · Nature · doi:10.1038/366727a0 · Cited by 372
Delocalization in inelastic scattering
Muller, D. A., & Silcox, J. (1995) · Ultramicroscopy · doi:10.1016/0304-3991(95)00029-z · Cited by 268
Self-citationMapping sp2 and sp3 states of carbon at sub-nanometre spatial resolution
Muller, D. A., Tzou, Y., Raj, R., & Silcox, J. (1993) · Nature · doi:10.1038/366725a0 · Cited by 243
Self-citationTrebbia, P., & Bonnet, N. (1990) · Ultramicroscopy · doi:10.1016/0304-3991(90)90070-3 · Cited by 183
Allen, L. J., Findlay, S. D., Lupini, A. R., Oxley, M. P., & Pennycook, S. J. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.105503 · Cited by 119
Cited by
One-Dimensional Electrical Contact to a Two-Dimensional Material
Wang, L., Meric, I., Huang, P. Y., Gao, Q., Gao, Y., Tran, H., Taniguchi, T., Watanabe, K., Campos, L. M., Muller, D. A., et al. (2013) · Science · doi:10.1126/science.1244358 · Cited by 3,042
Self-citationWang, D., Xin, H. L., Hovden, R., Wang, H., Yu, Y., Muller, D. A., DiSalvo, F. J., & Abruña, H. D. (2013) · Nature Materials · doi:10.1038/nmat3458 · Cited by 2,082
Self-citationOptical excitations in electron microscopy
García de Abajo, F. J. (2010) · Reviews of Modern Physics · doi:10.1103/revmodphys.82.209 · Cited by 1,463
Atom-by-atom structural and chemical analysis by annular dark-field electron microscopy
Krivanek, O. L., Chisholm, M. F., Nicolosi, V., Pennycook, T. J., Corbin, G. J., Dellby, N., Murfitt, M. F., Own, C. S., Szilagyi, Z. S., Oxley, M. P., et al. (2010) · Nature · doi:10.1038/nature08879 · Cited by 1,352
Self-citationPeriodic Segregation of Solute Atoms in Fully Coherent Twin Boundaries
Nie, J. F., Zhu, Y. M., Liu, J. Z., & Fang, X. Y. (2013) · Science · doi:10.1126/science.1229369 · Cited by 845
Metadata
- Authors
- Muller, D. A., Kourkoutis, L. F., Murfitt, M., Song, J. H., Hwang, H. Y., Silcox, J., Dellby, N., & Krivanek, O. L.
- Venue
- Science
- Published
- 2008-02-22
- Volume
- 319
- Issue
- 5866
- Pages
- 1073-1076
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2071410909
- Cited by
- 617
- References
- 8
- FWCI
- 32.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.