The DOI matches its Crossref record.
Flow Characteristics of Human Erythrocytes through Polycarbonate Sieves
Abstract
We used polycarbonate sieves with uniform cylindrical pores (2.4 to 6.8 microns in diameter) to filter suspensions of human erythrocytes (mean major diameter is 7.2 microns) in Eagle-albumin solution. With 6.8-micron sieves the pressure-flow curves are convexed to the pressure-axis at low pressures and become linear with high pressures. With 4.5-micron sieves, however, the pressure-flow relationship is linear throughout the range of study. In both types of sieves, flow rate is reduced progressively with increasing concentration of red blood cells (RBC) over a range of 0.5 to 95 percent. The resistance to flow of RBC suspensions is higher in 4.5-micron than in 6.8-micron pores. With filter pore diameters of 3.0 microns or more, the RBC concentration in the filtrate was 100 percent of that in the solution being filtered, but only 70 percent with 2.4-micron pores. The observed critical pore diameter for 100 percent cell transmission agrees with theoretical calculation based on the assumption that the RBC membrane is deformable but nonextensible. The importance of cell deformation in the passage of RBC's through small pores is shown by the inability of RBC hardened in acetaldehyde to pass pores with 6.8-micron diameter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Strain Energy Function of Red Blood Cell Membranes
Skalak, R., Tozeren, A., Zarda, R. P., & Chien, S. (1973) · Biophysical Journal · doi:10.1016/s0006-3495(73)85983-1 · Cited by 832
Self-citationMetabolic dependence of red cell deformability
Weed, R. I., LaCelle, P. L., & Merrill, E. W. (1969) · Journal of Clinical Investigation · doi:10.1172/jci106038 · Cited by 820
Improved measurements of the erythrocyte geometry
Evans, E., & Fung, Y.-C. (1972) · Microvascular Research · doi:10.1016/0026-2862(72)90069-6 · Cited by 592
A simple method for measuring erythrocyte deformability.
Reid, H. L., Barnes, A. J., Lock, P. J., Dormandy, J. A., & Dormandy, T. L. (1976) · Journal of Clinical Pathology · doi:10.1136/jcp.29.9.855 · Cited by 464
Microvascular Rheology and Hemodynamics
LIPOWSKY, H. H. (2005) · Microcirculation · doi:10.1080/10739680590894966 · Cited by 414
Deformation of Red Blood Cells in Capillaries
Skalak, R., & Brånemark, P. I. (1969) · Science · doi:10.1126/science.164.3880.717 · Cited by 358
Reduced Erythrocyte Deformability in Diabetes
McMillan, D. E., Utterback, N. G., & Puma, J. L. (1978) · Diabetes · doi:10.2337/diab.27.9.895 · Cited by 347
Biophysical Behavior of Red Cells in Suspensions
CHIEN, S. (1975) · The Red Blood Cell · doi:10.1016/b978-0-12-677202-9.50019-8 · Cited by 349
Self-citationBlood Viscosity: Influence of Erythrocyte Deformation
Chien, S., Usami, S., Dellenback, R. J., & Gregersen, M. I. (1967) · Science · doi:10.1126/science.157.3790.827 · Cited by 284
Self-citation
Metadata
- Authors
- Gregersen, M. I., Bryant, C. A., Hammerle, W. E., Usami, S., & Chien, S.
- Venue
- Science
- Published
- 1967-08-18
- Volume
- 157
- Issue
- 3790
- Pages
- 825-827
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2071354653
- Cited by
- 185
- References
- 0
- FWCI
- 19.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.