The DOI matches its Crossref record.
Rheological Comparison of Hemoglobin Solutions and Erythrocyte Suspensions
Abstract
Hemoglobin solutions prepared from hemolyzed human erythrocyte packs have Newtonian flow properties. Diluted solutions are also Newtonian. All solutions have a viscosity lower than the apparent viscosity of erythrocyte suspensions of equal oxygen-carrying capacity. The presence of cell debris in hemoglobin solutions causes non-Newtonian (pseudoplastic or rheopectic) flow behavior.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomechanics and biophysics of cancer cells☆
SURESH, S. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.04.002 · Cited by 1,284
Red cell membrane: past, present, and future
Mohandas, N., & Gallagher, P. G. (2008) · Blood · doi:10.1182/blood-2008-07-161166 · Cited by 1,089
Shear Dependence of Effective Cell Volume as a Determinant of Blood Viscosity
Chien, S. (1970) · Science · doi:10.1126/science.168.3934.977 · Cited by 421
Abnormal rheology of oxygenated blood in sickle cell anemia
Chien, S., Usami, S., & Bertles, J. F. (1970) · Journal of Clinical Investigation · doi:10.1172/jci106273 · Cited by 356
Reduced Erythrocyte Deformability in Diabetes
McMillan, D. E., Utterback, N. G., & Puma, J. L. (1978) · Diabetes · doi:10.2337/diab.27.9.895 · Cited by 347
Metadata
- Authors
- Cokelet, G. R., & Meiselman, H. J.
- Venue
- Science
- Published
- 1968-10-11
- Volume
- 162
- Issue
- 3850
- Pages
- 275-277
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2085831998
- Cited by
- 172
- References
- 0
- FWCI
- 13.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rheological Comparison of Hemoglobin Solutions and Erythrocyte Suspensions. https://app.cochat.ai/papers/10.1126/science.162.3850.275
- The paper
- Cokelet, G. R., & Meiselman, H. J. (1968). Rheological Comparison of Hemoglobin Solutions and Erythrocyte Suspensions. Science. https://doi.org/10.1126/science.162.3850.275
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.