The DOI matches its Crossref record.
Fluid Drop-Like Transition of Erythrocytes under Shear
Abstract
Red cells dispersed in a continuous medium of high viscosity possess the flow properties of fluid drops. The cells at rest are biconcave, while under shear they become progressively deformed into prolate ellipsoids, their long axis aligned parallel to the flow direction. The red cell membrane rotates around the hemoglobin like a tread of a tank. At high rates of shear this mechanism greatly reduces viscosity at all hematocrit values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sickle Cell Hemoglobin Polymerization
Eaton, W. A., & Hofrichter, J. (1990) · Advances in Protein Chemistry · doi:10.1016/s0065-3233(08)60287-9 · Cited by 623
Fischer, T. M., Stöhr-Liesen, M., & Schmid-Schönbein, H. (1978) · Science · doi:10.1126/science.715448 · Cited by 427
Self-citationShear Dependence of Effective Cell Volume as a Determinant of Blood Viscosity
Chien, S. (1970) · Science · doi:10.1126/science.168.3934.977 · Cited by 421
Large deformation of red blood cell ghosts in a simple shear flow
Eggleton, C. D., & Popel, A. S. (1998) · Physics of Fluids · doi:10.1063/1.869703 · Cited by 362
Abnormal rheology of oxygenated blood in sickle cell anemia
Chien, S., Usami, S., & Bertles, J. F. (1970) · Journal of Clinical Investigation · doi:10.1172/jci106273 · Cited by 356
Metadata
- Authors
- Schmid-Schönbein, H., & Wells, R.
- Venue
- Science
- Published
- 1969-07-18
- Volume
- 165
- Issue
- 3890
- Pages
- 288-291
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2039417241
- Cited by
- 319
- References
- 0
- FWCI
- 20.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluid Drop-Like Transition of Erythrocytes under Shear. https://app.cochat.ai/papers/10.1126/science.165.3890.288
- The paper
- Schmid-Schönbein, H., & Wells, R. (1969). Fluid Drop-Like Transition of Erythrocytes under Shear. Science. https://doi.org/10.1126/science.165.3890.288
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.