The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Patterned Condensation Figures as Optical Diffraction Gratings
Abstract
Heterogeneous, patterned surfaces comprising well-defined hydrophobic and hydrophilic regions and having micrometer-scale periodicities were prepared by patterning the adsorption of ω-functionalized alkanethiolates in self-assembled monolayers (SAMs) on gold. Condensation of water on such surfaces resulted in drops that followed the patterns in the SAMs. These patterned condensation figures (CFs) acted as optical diffraction gratings for reflected (or transmitted) light from a helium-neon laser (wavelength of 632.8 nanometers). Under an atmosphere of constant relative humidity, the development of the condensation figure was monitored quantitatively, as the temperature of the surface was lowered, by following the change in intensity of a first-order diffraction spot. This experimental technique may be useful in the development of new types of optical sensors that respond to their environment by changing the reflectivity of patterned regions and for studying phenomena such as drop nucleation, contact angle hysteresis, and spontaneous dewetting and break-up of thin liquid films.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kumar, A., & Whitesides, G. M. (1993) · Applied Physics Letters · doi:10.1063/1.110628 · Cited by 1,605
Self-citationFolkers, J. P., Laibinis, P. E., & Whitesides, G. M. (1992) · Langmuir · doi:10.1021/la00041a015 · Cited by 393
Self-citationBeysens, D., & Knobler, C. M. (1986) · Physical Review Letters · doi:10.1103/physrevlett.57.1433 · Cited by 314
Scanning electron microscopy can form images of patterns in self-assembled monolayers
López, G. P., Biebuyck, H. A., & Whitesides, G. M. (1993) · Langmuir · doi:10.1021/la00030a015 · Cited by 135
Self-citation
Cited by
Continuous Convective Assembling of Fine Particles into Two-Dimensional Arrays on Solid Surfaces
Dimitrov, A. S., & Nagayama, K. (1996) · Langmuir · doi:10.1021/la9502251 · Cited by 956
Nanosized Particles Made in Colloidal Assemblies
Pileni, M. P. (1997) · Langmuir · doi:10.1021/la960319q · Cited by 831
Synthesis, structure and properties of metal nanoclusters
Wilcoxon, J. P., & Abrams, B. L. (2006) · Chemical Society Reviews · doi:10.1039/b517312b · Cited by 760
Teranishi, T., Hosoe, M., Tanaka, T., & Miyake, M. (1999) · The Journal of Physical Chemistry B · doi:10.1021/jp983478m · Cited by 662
Tadanaga, K., Morinaga, J., Matsuda, A., & Minami, T. (2000) · Chemistry of Materials · doi:10.1021/cm990643h · Cited by 470
Metadata
- Authors
- Kumar, A., & Whitesides, G. M.
- Venue
- Science
- Published
- 1994-01-07
- Volume
- 263
- Issue
- 5143
- Pages
- 60-62
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2017033059
- Cited by
- 329
- References
- 4
- FWCI
- 11.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.