The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Microfabrication Inside Capillaries Using Multiphase Laminar Flow Patterning
Abstract
The reaction of species in solutions flowing laminarly (without turbulent mixing) inside capillaries was used as the basis for a broadly applicable method of microfabrication. In this method, patterning occurs as a result of transport of reactive species to interfaces within the capillary by laminar flow. A wide range of chemistries can be used to generate structures with feature sizes of less than 5 micrometers and with spatial localization to within 5 micrometers. The method is applicable to the patterning of metals, organic polymers, inorganic crystals, and ceramics on the inner walls of preformed capillaries, using both additive and subtractive processes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Self-citationReynolds, O. (1883) · Philosophical Transactions of the Royal Society of London · doi:10.1098/rstl.1883.0029 · Cited by 2,262
Fundamentals of Microfabrication
(2016) · Micromechatronics · doi:10.1201/b15830-17 · Cited by 2,109
IV. On the dynamical theory of incompressible viscous fluids and the determination of the criterion
Reynolds, O. (1895) · Philosophical Transactions of the Royal Society of London. (A.) · doi:10.1098/rsta.1895.0004 · Cited by 1,436
Biotechnology at low Reynolds numbers
Brody, J. P., Yager, P., Goldstein, R. E., & Austin, R. H. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79538-3 · Cited by 523
Microfluidic Diffusion-Based Separation and Detection
Weigl, B. H., & Yager, P. (1999) · Science · doi:10.1126/science.283.5400.346 · Cited by 502
Walsh, D., Hopwood, J. D., & Mann, S. (1994) · Science · doi:10.1126/science.264.5165.1576 · Cited by 192
Aizenberg, J., Black, A. J., & Whitesides, G. M. (1998) · Nature · doi:10.1038/29730 · Cited by 188
Self-citationChemiluminescence and Bioluminescence
(1973) · Springer eBooks · doi:10.1007/978-1-4757-0638-3 · Cited by 175
Evolution of Biomineralization
Lowenstam, H. A., & Weiner, S. (1989) · Oxford University Press eBooks · doi:10.1093/oso/9780195049770.003.0014 · Cited by 142
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Self-citationSoft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Self-citation
Metadata
- Authors
- Kenis, P. J. A., Ismagilov, R. F., & Whitesides, G. M.
- Venue
- Science
- Published
- 1999-07-02
- Volume
- 285
- Issue
- 5424
- Pages
- 83-85
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2017581879
- Cited by
- 659
- References
- 10
- FWCI
- 26.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.