Electrophysiological Signs of Split-Second Decision-Making
The DOI matches its Crossref record.
Abstract
When young adults detected auditory stimuli at split-second intervals, different components of the event-related brain potentials showed markedly different speeds of recovery. The P 3 component (latency 300 to 350 milliseconds) was fully recovered at intervals of less than 1.0 second, while the N 1 —P 2 components (latencies 100 to 180 milliseconds) were markedly attenuated with stimulus repetition even at longer interstimulus intervals. Thus, the N 1 —P 2 recovers much more slowly than a subject's ability to evaluate signals, whereas the P 3 appears to be generated at the same high rates as the decision processes with which it is associated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Näätänen, R., & Picton, T. (1987) · Psychophysiology · doi:10.1111/j.1469-8986.1987.tb00311.x · Cited by 3,321
Decision making, the P3, and the locus coeruleus–norepinephrine system
Nieuwenhuis, S., Aston-Jones, G., & Cohen, J. D. (2005) · Psychological Bulletin · doi:10.1037/0033-2909.131.4.510 · Cited by 1,678
A supramodal accumulation-to-bound signal that determines perceptual decisions in humans
O'Connell, R. G., Dockree, P. M., & Kelly, S. P. (2012) · Nature Neuroscience · doi:10.1038/nn.3248 · Cited by 755
Interactions between sentence context and word frequencyinevent-related brainpotentials
Van Petten, C., & Kutas, M. (1990) · Memory & Cognition · doi:10.3758/bf03197127 · Cited by 681
A brief introduction to the use of event-related potentials in studies of perception and attention
Woodman, G. F. (2010) · Attention Perception & Psychophysics · doi:10.3758/app.72.8.2031 · Cited by 632
Electrophysiology of Cognition
Hillyard, S. A., & Picton, T. W. (1987) · Comprehensive Physiology · doi:10.1002/cphy.cp010513 · Cited by 391
Self-citationAttentional modulation of human auditory cortex
Petkov, C. I., Kang, X., Alho, K., Bertrand, O., Yund, E. W., & Woods, D. L. (2004) · Nature Neuroscience · doi:10.1038/nn1256 · Cited by 333
Self-citationAge‐related changes in scalp topography to novel and target stimuli
FRIEDMAN, D., SIMPSON, G., & HAMBERGER, M. (1993) · Psychophysiology · doi:10.1111/j.1469-8986.1993.tb02060.x · Cited by 252
P300 in Clinical Applications: Meaning, Method, and Measurement
Polich, J. (1991) · American Journal of EEG Technology · doi:10.1080/00029238.1991.11080373 · Cited by 217
The Role of the Locus Coeruleus in Mediating the Attentional Blink: A Neurocomputational Theory.
Nieuwenhuis, S., Gilzenrat, M. S., Holmes, B. D., & Cohen, J. D. (2005) · Journal of Experimental Psychology: General · doi:10.1037/0096-3445.134.3.291 · Cited by 181
Novelty P3 elicited by the subject’s own name in comatose patients
Fischer, C., Dailler, F., & Morlet, D. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.03.035 · Cited by 164
“The cognitive component P300 is ideally elicited in an active oddball paradigm in which a rare target stimulus is discriminated from a frequent standard stimulus one (Squires et al., 1976; Woods et al., 1980).”
Second Thoughts: Multiple P300s Elicited by a Single Stimulus
Johnson, R., & Donchin, E. (1985) · Psychophysiology · doi:10.1111/j.1469-8986.1985.tb01584.x · Cited by 159
“Another line of evidence consistent with the idea that our multiple positive peaks are multiple P3OOs is the P300 recovery cycle data reported by Woods, Hillyard, Courchesne, and Galambos (1980) .”
ResultP300 from a passive auditory paradigm
Polich, J. (1989) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(89)90061-0 · Cited by 159
Metadata
- Authors
- Woods, D. L., Hillyard, S. A., Courchesne, E., & Galambos, R.
- Venue
- Science
- Published
- 1980-02-08
- Volume
- 207
- Issue
- 4431
- Pages
- 655-657
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1999224987
- Cited by
- 49
- References
- 0
- FWCI
- 1.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.