The DOI matches its Crossref record.
Detection of Transient Protein Folding Populations by Mass Spectrometry
Abstract
Hydrogen-deuterium exchange measurements are becoming increasingly important in studies of the dynamics of protein molecules and, particularly, of their folding behavior. Electrospray ionization mass spectrometry (ESI-MS) has been used to obtain the distribution of masses within a population of protein molecules that had undergone hydrogen exchange in solution. This information is complementary to that from nuclear magnetic resonance spectroscopy (NMR) experiments, which measure the average occupancy of individual sites over the distribution of protein molecules. In experiments with hen lysozyme, a combination of ESI-MS and NMR was used to distinguish between alternative mechanisms of hydrogen exchange, providing insight into the nature and populations of transient folding intermediates. These results have helped to detail the pathways available to a protein during refolding.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
From Levinthal to pathways to funnels
Dill, K. A., & Chan, H. S. (1997) · Nature Structural & Molecular Biology · doi:10.1038/nsb0197-10 · Cited by 2,293
Understanding how proteins fold: the lysozyme story so far
Dobson, C. M., Evans, P. A., & Radford, S. E. (1994) · Trends in Biochemical Sciences · doi:10.1016/0968-0004(94)90171-6 · Cited by 340
Self-citationDetection of amyloid fibrils in Parkinson’s disease using plasmonic chirality
Kumar, J., Eraña, H., López-Martínez, E., Claes, N., Martín, V. F., Solís, D. M., Bals, S., Cortajarena, A. L., Castilla, J., & Liz-Marzán, L. M. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1721690115 · Cited by 312
Tuma, R., Coward, L. U., Kirk, M. C., Barnes, S., & Prevelige, P. E. (2001) · Journal of Molecular Biology · doi:10.1006/jmbi.2000.4383 · Cited by 53
Mass spectrometry: From plasma proteins to mitochondrial membranes
Robinson, C. V. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1820450116 · Cited by 53
Self-citation
Metadata
- Authors
- Miranker, A., Robinson, C. V., Radford, S. E., Aplin, R. T., & Dobson, C. M.
- Venue
- Science
- Published
- 1993-11-05
- Volume
- 262
- Issue
- 5135
- Pages
- 896-900
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2008818819
- Cited by
- 546
- References
- 0
- FWCI
- 20.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Transient Protein Folding Populations by Mass Spectrometry. https://app.cochat.ai/papers/10.1126/science.8235611
- The paper
- Miranker, A., Robinson, C. V., Radford, S. E., Aplin, R. T., & Dobson, C. M. (1993). Detection of Transient Protein Folding Populations by Mass Spectrometry. Science. https://doi.org/10.1126/science.8235611
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.