The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Submillisecond organic synthesis: Outpacing Fries rearrangement through microfluidic rapid mixing
Abstract
Rapid mixing to race past rearrangement: Chemistry relies on encounters between reactive partners. Sometimes one of the partners changes shape during the wait, spoiling the desired outcome. Kim et al. designed a microfluidic device to keep such botched encounters from happening. The device operates at low temperatures to keep individual reactants from isomerizing. It also achieves fast flow rates to maximize encounters between reactants on a microsecond time scale. The authors showcase the device by achieving bimolecular carbon-carbon coupling before one of the reagents can undergo a Fries rearrangement that would shift a neighboring group to the coupling site. Science , this issue p. 691
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
The past, present and potential for microfluidic reactor technology in chemical synthesis
Elvira, K. S., i Solvas, X. C., Wootton, R. C. R., & deMello, A. J. (2013) · Nature Chemistry · doi:10.1038/nchem.1753 · Cited by 1,203
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
Flash Chemistry: Fast Chemical Synthesis by Using Microreactors
Yoshida, J., Nagaki, A., & Yamada, T. (2008) · Chemistry – A European Journal · doi:10.1002/chem.200800582 · Cited by 537
Self-citationThe development of chaotic advection
Aref, H. (2002) · Physics of Fluids · doi:10.1063/1.1458932 · Cited by 497
Green and Sustainable Chemical Synthesis Using Flow Microreactors
Yoshida, J., Kim, H., & Nagaki, A. (2011) · ChemSusChem · doi:10.1002/cssc.201000271 · Cited by 442
Self-citationMultistep continuous-flow synthesis of (R)- and (S)-rolipram using heterogeneous catalysts
Tsubogo, T., Oyamada, H., & Kobayashi, S. (2015) · Nature · doi:10.1038/nature14343 · Cited by 396
Viscosity–temperature correlation for liquids
Seeton, C. J. (2006) · Tribology Letters · doi:10.1007/s11249-006-9071-2 · Cited by 280
A flow-microreactor approach to protecting-group-free synthesis using organolithium compounds
Kim, H., Nagaki, A., & Yoshida, J.-I. (2011) · Nature Communications · doi:10.1038/ncomms1264 · Cited by 246
Self-citationTools for chemical synthesis in microsystems
Jensen, K. F., Reizman, B. J., & Newman, S. G. (2014) · Lab Chip · doi:10.1039/c4lc00330f · Cited by 217
Machine‐Assisted Organic Synthesis
Ley, S. V., Fitzpatrick, D. E., Myers, R. M., Battilocchio, C., & Ingham, R. J. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201501618 · Cited by 216
Viscosity-Temperature Correlation for Liquids
Seeton, C. J. (2006) · doi:10.1115/ijtc2006-12139 · Cited by 153
Bringmann, G., Menche, D., Kraus, J., Mühlbacher, J., Peters, K., Peters, E. ‐., Brun, R., Bezabih, M., & Abegaz, B. (2002) · The Journal of Organic Chemistry · doi:10.1021/jo020189s · Cited by 84
Min, K., Lee, T., Park, C. P., Wu, Z., Girault, H. H., Ryu, I., Fukuyama, T., Mukai, Y., & Kim, D. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.201002004 · Cited by 74
Self-citationMin, K., Im, D. J., Lee, H., & Kim, D. (2014) · Lab on a Chip · doi:10.1039/c4lc00700j · Cited by 60
Self-citationMin, K., Kim, J., Kim, H., Im, D. J., & Kim, D. (2016) · Lab on a Chip · doi:10.1039/c5lc01585e · Cited by 14
Self-citationHessel, V., Shahbazali, E., Noël, T., & Зеленцов, С. В. (2014) · ChemBioEng Reviews · doi:10.1002/cben.201400022 · Cited by 10
Cited by
The Hitchhiker’s Guide to Flow Chemistry
Plutschack, M. B., Pieber, B., Gilmore, K., & Seeberger, P. H. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00183 · Cited by 1,995
Expanding the medicinal chemistry synthetic toolbox
Boström, J., Brown, D. G., Young, R. J., & Keserü, G. M. (2018) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2018.116 · Cited by 665
A field guide to flow chemistry for synthetic organic chemists
Capaldo, L., Wen, Z., & Noël, T. (2023) · Chemical Science · doi:10.1039/d3sc00992k · Cited by 402
Interplay between materials and microfluidics
Hou, X., Zhang, Y. S., Santiago, G. T.-D., Alvarez, M. M., Ribas, J., Jonas, S. J., Weiss, P. S., Andrews, A. M., Aizenberg, J., & Khademhosseini, A. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.16 · Cited by 387
Lin, S., Yu, Z., Chen, D., Wang, Z., Miao, J., Li, Q., Zhang, D., Song, J., & Cui, D. (2020) · Small · doi:10.1002/smll.201903916 · Cited by 353
Metadata
- Authors
- Kim, H., Min, K.-I., Inoue, K., Im, D. J., Kim, D.-P., & Yoshida, J.-I.
- Venue
- Science
- Published
- 2016-05-06
- Volume
- 352
- Issue
- 6286
- Pages
- 691-694
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2346720530
- Cited by
- 271
- References
- 17
- FWCI
- 15.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.