Breaking Lorentz reciprocity to overcome the time-bandwidth limit in physics and engineering
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Resonant systems with high bandwidth: The performance of an active system, whether it is optical, electrical, or mechanical, is often described by its quality ( Q ) factor. Typically, one learns the rule that the higher the Q factor, the sharper the resonance—that is, the bandwidth of the device is reduced. Tsakmakidis et al. show that this is indeed the case, but only for symmetric systems. However, for the case of asymmetric (or nonreciprocal) systems, the rule need not be obeyed. They show theoretically that the more asymmetric a system with high Q is, the wider the bandwidth can be. The effect raises the prospect of designing high- Q devices operating over large bandwidths. Science , this issue p. 1260
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Colloquium : Topological insulators
Hasan, M. Z., & Kane, C. L. (2010) · Reviews of Modern Physics · doi:10.1103/revmodphys.82.3045 · Cited by 19,930
Vahala, K. J. (2003) · Nature · doi:10.1038/nature01939 · Cited by 4,878
Photonic Floquet topological insulators
Rechtsman, M. C., Zeuner, J. M., Plotnik, Y., Lumer, Y., Podolsky, D., Dreisow, F., Nolte, S., Segev, M., & Szameit, A. (2013) · Nature · doi:10.1038/nature12066 · Cited by 3,332
Cited by
Electromagnetic Nonreciprocity
Caloz, C., Alù, A., Tretyakov, S., Sounas, D., Achouri, K., & Deck-Léger, Z.-L. (2018) · Physical Review Applied · doi:10.1103/physrevapplied.10.047001 · Cited by 644
Optical meta-waveguides for integrated photonics and beyond
Meng, Y., Chen, Y., Lu, L., Ding, Y., Cusano, A., Fan, J. A., Hu, Q., Wang, K., Xie, Z., Liu, Z., et al. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00655-x · Cited by 464
Metadata
- Authors
- Tsakmakidis, K. L., Shen, L., Schulz, S. A., Zheng, X., Upham, J., Deng, X., Altug, H., Vakakis, A. F., & Boyd, R. W.
- Venue
- Science
- Published
- 2017-06-23
- Volume
- 356
- Issue
- 6344
- Pages
- 1260-1264
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2693790197
- Cited by
- 236
- References
- 3
- FWCI
- 9.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.