The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
New refrigerants and system configurations for vapor-compression refrigeration
Abstract
The high global warming potential of current refrigerants in cooling equipment based on the vapor-compression cycle has triggered a major effort to find and implement more environmentally benign alternatives. Here, we review the basics of the vapor-compression cycle together with the safety, environmental, and thermodynamic constraints that have led to the current and next generation of refrigerants. The development of new fluids has focused on fluorinated olefins, known as hydrofluoroolefins (HFOs), and blends that contain HFOs. Many of these are slightly flammable, presenting trade-offs between safety and environmental considerations. Engineers also have options with a resurgence of the “natural refrigerants” (ammonia, carbon dioxide, propane, and isobutane). Innovative system designs that reduce the required quantity of refrigerant may allow a wider choice of refrigerants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in thermoelectric materials research: Looking back and moving forward
He, J., & Tritt, T. M. (2017) · Science · doi:10.1126/science.aak9997 · Cited by 2,767
On the depletion of Antarctic ozone
Solomon, S., Garcia, R. R., Rowland, F. S., & Wuebbles, D. J. (1986) · Nature · doi:10.1038/321755a0 · Cited by 1,558
The importance of the Montreal Protocol in protecting climate
Velders, G. J. M., Andersen, S. O., Daniel, J. S., Fahey, D. W., & McFarland, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610328104 · Cited by 562
Limited options for low-global-warming-potential refrigerants
McLinden, M. O., Brown, J. S., Brignoli, R., Kazakov, A. F., & Domanski, P. A. (2017) · Nature Communications · doi:10.1038/ncomms14476 · Cited by 541
Self-citationThe large contribution of projected HFC emissions to future climate forcing
Velders, G. J. M., Fahey, D. W., Daniel, J. S., McFarland, M., & Andersen, S. O. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0902817106 · Cited by 424
Review of alternative cooling technologies
Steven Brown, J., & Domanski, P. A. (2014) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2013.12.014 · Cited by 313
Richter, M., McLinden, M. O., & Lemmon, E. W. (2011) · Journal of Chemical & Engineering Data · doi:10.1021/je200369m · Cited by 238
Self-citationSolomon, K. R., Velders, G. J. M., Wilson, S. R., Madronich, S., Longstreth, J., Aucamp, P. J., & Bornman, J. F. (2016) · Journal of Toxicology and Environmental Health, Part B · doi:10.1080/10937404.2016.1175981 · Cited by 213
Velders, G. J. M., Fahey, D. W., Daniel, J. S., Andersen, S. O., & McFarland, M. (2015) · Atmospheric Environment · doi:10.1016/j.atmosenv.2015.10.071 · Cited by 179
Low-GWP refrigerants for medium and high-pressure applications
Domanski, P. A., Brignoli, R., Brown, J. S., Kazakov, A. F., & McLinden, M. O. (2017) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.08.019 · Cited by 124
Self-citation
Cited by
Materials, physics and systems for multicaloric cooling
Hou, H., Qian, S., & Takeuchi, I. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00428-x · Cited by 288
Zhang, P., Wang, Z., Wang, F., & Ma, L. (2025) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2025.125925 · Cited by 8
Metadata
- Authors
- McLinden, M. O., Seeton, C. J., & Pearson, A.
- Venue
- Science
- Published
- 2020-11-13
- Volume
- 370
- Issue
- 6518
- Pages
- 791-796
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W3105206763
- Cited by
- 292
- References
- 15
- FWCI
- 12.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: New refrigerants and system configurations for vapor-compression refrigeration. https://app.cochat.ai/papers/10.1126/science.abe3692
- The paper
- McLinden, M. O., Seeton, C. J., & Pearson, A. (2020). New refrigerants and system configurations for vapor-compression refrigeration. Science. https://doi.org/10.1126/science.abe3692
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.