A Computational Model to Predict the Effects of Class I Anti-Arrhythmic Drugs on Ventricular Rhythms
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Two- and three-dimensional models of cardiac excitability based on sodium channel kinetics can predict the adverse effects of class I anti-arrhythmic drugs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rohr, S., Kucera, J. P., & Kléber, A. G. (1998) · Circulation Research · doi:10.1161/01.res.83.8.781 · Cited by 271 · cited 2×
“…that flecainide combined with reduced I Na (because of the reduced diastolic intervals stemming from APD prolongation) allow for ultraslow Ca 2+ -supported conduction that promotes development of reentrant arrhythmias even when spon-taneous ventricular ectopy occurs outside of the VW ( 43 , 44 ).”
BackgroundIs heart size a factor in ventricular fibrillation? Or how close are rabbit and human hearts?
Panfilov, A. V. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2005.12.022 · Cited by 106 · cited 1×
“However, an analysis (details in the Supplementary Material) revealed analogous dynamics when the effective tissue sizes in the simulation and exper-iment were compared ( 38 ) in Figs.”
Result
Cited by
A Review on Applications of Computational Methods in Drug Screening and Design
Lin, X., Li, X., & Lin, X. (2020) · Molecules · doi:10.3390/molecules25061375 · Cited by 718
“Drug interactions with cardiac ion channels have been modeled at the atomic scale in simulated docking and MD simulations, as well as at the level of channel function to simulate drug effects on channel behavior [32, [94] [95] [96] [97] [98] [99] [100] .”
BackgroundMultiscale Computational Models of Complex Biological Systems
Walpole, J., Papin, J. A., & Peirce, S. M. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150104 · Cited by 244
Chabiniok, R., Wang, V. Y., Hadjicharalambous, M., Asner, L., Lee, J., Sermesant, M., Kuhl, E., Young, A. A., Moireau, P., Nash, M. P., et al. (2016) · Interface Focus · doi:10.1098/rsfs.2015.0083 · Cited by 234
Computational Medicine: Translating Models to Clinical Care
Winslow, R. L., Trayanova, N., Geman, D., & Miller, M. I. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3003528 · Cited by 202
“It is now possible to collect the experimental data needed to constrain models of ion channel gating and drug binding, and use these data to test hypotheses regarding mechanisms of drug action on heart cells and tissues ( 79 , 80 ) as well as whole heart ( 81 ).”
BackgroundSelf-citationTerrenoire, C., Wang, K., Chan Tung, K. W., Chung, W. K., Pass, R. H., Lu, J. T., Jean, J.-C., Omari, A., Sampson, K. J., Kotton, D. N., et al. (2013) · Journal of General Physiology · doi:10.1085/jgp.201210899 · Cited by 195
Self-citation
Metadata
- Authors
- Moreno, J. D., Zhu, Z. I., Yang, P.-C., Bankston, J. R., Jeng, M.-T., Kang, C., Wang, L., Bayer, J. D., Christini, D. J., Trayanova, N. A., Ripplinger, C. M., Kass, R. S., & Clancy, C. E.
- Venue
- Science Translational Medicine
- Published
- 2011-08-31
- Volume
- 3
- Issue
- 98
- Pages
- 98ra83-98ra83
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W1991781357
- Cited by
- 203
- References
- 2
- FWCI
- 11.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Computational Model to Predict the Effects of Class I Anti-Arrhythmic Drugs on Ventricular Rhythms. https://app.cochat.ai/papers/10.1126/scitranslmed.3002588
- The paper
- Moreno, J. D., Zhu, Z. I., Yang, P.-C., Bankston, J. R., Jeng, M.-T., Kang, C., Wang, L., Bayer, J. D., Christini, D. J., Trayanova, N. A., Ripplinger, C. M., Kass, R. S., & Clancy, C. E. (2011). A Computational Model to Predict the Effects of Class I Anti-Arrhythmic Drugs on Ventricular Rhythms. Science Translational Medicine. https://doi.org/10.1126/scitranslmed.3002588
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.