Abstract

A megabore column gas-liquid chromatographic method which uses nitrogen-phosphorus detection was developed for the analysis of fluconazole in plasma, serum, cerebrospinal fluid, or urine. The assay was linear from 0.2 to 200 micrograms/ml and had an average coefficient of variation of 7%. The suitability of the assay for pharmacokinetic studies was demonstrated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/aac.33.5.714

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 54

Metadata

Authors
Harris, S. C., Wallace, J. E., Foulds, G., & Rinaldi, M. G.
Venue
Antimicrobial Agents and Chemotherapy
Published
1989-05
Volume
33
Issue
5
Pages
714-716
ISSN
  • 0066-4804 (ISSN-L)
  • 1098-6596
OpenAlex
W2020426892
Cited by
54
References
0
FWCI
6.79
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assay of fluconazole by megabore capillary gas-liquid chromatography with nitrogen-selective detection. https://app.cochat.ai/papers/10.1128/aac.33.5.714
The paper
Harris, S. C., Wallace, J. E., Foulds, G., & Rinaldi, M. G. (1989). Assay of fluconazole by megabore capillary gas-liquid chromatography with nitrogen-selective detection. Antimicrobial Agents and Chemotherapy. https://doi.org/10.1128/aac.33.5.714

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.