Activities of a Nitrofurazone-Containing Urinary Catheter and a Silver Hydrogel Catheter against Multidrug-Resistant Bacteria Characteristic of Catheter-Associated Urinary Tract Infection
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The in vitro inhibitory activity of a nitrofurazone-coated urinary catheter (NFC) against 86 recently obtained susceptible and multidrug-resistant (MDR) clinical isolates of Escherichia coli , Klebsiella pneumoniae , Citrobacter freundii , Staphylococcus aureus , coagulase-negative staphylococci , and Enterococcus faecium , which are species implicated in catheter-associated urinary tract infection and which traditionally have been susceptible to nitrofuran derivatives, was determined using an agar diffusion assay. In a subset of these strains, the activity of the NFC was compared with that of a silver hydrogel urinary catheter (SHC), and the durability of each catheter’s inhibitory activity was assessed during serial daily transfers of catheter segments to fresh culture plates. Except for vancomycin-resistant E. faecium , the NFC was active against all isolates tested and showed comparable inhibition zones with susceptible and MDR strains of each species. In contrast, the SHC inhibited only certain staphylococci ( P < 0.01 versus the NFC), and among these strains, the SHC produced smaller inhibition zones than did the NFC ( P < 0.01). Inhibition was evident for up to 5 days with the NFC, but for only 1 day (if at all) with the SHC ( P < 0.01). These data document that, for most genera which traditionally have been susceptible to nitrofuran derivatives, the NFC remains active against contemporary MDR isolates. They also demonstrate that the in vitro antibacterial activity of the NFC is markedly superior to that of the SHC in several respects. Thus, the NFC shows promise for clinical use in the current era of MDR bacteria.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exacerbations of multiple sclerosis in patients treated with gamma interferon
Panitch, H., Haley, A., Hirsch, R., & Johnson, K. (1987) · The Lancet · doi:10.1016/s0140-6736(87)92863-7 · Cited by 1,071
Cited by
Biofilms: Survival Mechanisms of Clinically Relevant Microorganisms
Donlan, R. M., & Costerton, J. W. (2002) · Clinical Microbiology Reviews · doi:10.1128/cmr.15.2.167-193.2002 · Cited by 6,644
Hooton, T. M., Bradley, S. F., Cardenas, D. D., Colgan, R., Geerlings, S. E., Rice, J. C., Saint, S., Schaeffer, A. J., Tambayh, P. A., Tenke, P., et al. (2010) · Clinical Infectious Diseases · doi:10.1086/650482 · Cited by 2,099
Nosocomial infections in adult intensive-care units
Vincent, J.-L. (2003) · The Lancet · doi:10.1016/s0140-6736(03)13644-6 · Cited by 705
EAU Guidelines for the Management of Urinary and Male Genital Tract Infections1
Naber, K. G., Bergman, B., Bishop, M. C., Bjerklund-Johansen, T. E., Botto, H., Lobel, B., Cruz, F. J., & Selvaggi, F. P. (2001) · European Urology · doi:10.1159/000049840 · Cited by 510
Role of biofilm in catheter-associated urinary tract infection☆
Trautner, B. W., & Darouiche, R. O. (2004) · American Journal of Infection Control · doi:10.1016/j.ajic.2003.08.005 · Cited by 455
Metadata
- Authors
- Johnson, J. R., Delavari, P., & Azar, M.
- Venue
- Antimicrobial Agents and Chemotherapy
- Publisher
- American Society for Microbiology
- Published
- 1999-12
- Volume
- 43
- Issue
- 12
- Pages
- 2990-2995
- ISSN
- 0066-4804 (ISSN-L)
- 1098-6596
- OpenAlex
- W2146516629
- Cited by
- 107
- References
- 1
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.