CoChat

Reversion of the Glycopeptide Resistance Phenotype in Staphylococcus aureus Clinical Isolates

Open access
Boyle-Vavra, Susan, Berke, Sarah K., Lee, Jean C., Daum, Robert S. · 2000 · Antimicrobial Agents and Chemotherapy
Cited by 121

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The recent identification of glycopeptide intermediate-resistant Staphylococcus aureus (GISA) clinical isolates has provided an opportunity to assess the stability of the glycopeptide resistance phenotype by nonselective serial passage and to evaluate reversion-associated cell surface changes. Three GISA isolates from the United States (MIC of vancomycin = 8 μg/ml) and two from Japan (MICs of vancomycin = 8 and 2 μg/ml) were passaged daily on nutrient agar with or without vancomycin supplementation. After 15 days of passage on nonselective medium, vancomycin- and teicoplanin-susceptible revertants were obtained from each GISA isolate as determined by broth dilution MIC. Revertant isolates were compared with parent isolates for changes in vancomycin heteroresistance, capsule production, hemolysis phenotype, coagulase activity, and lysostaphin susceptibility. Several revertants lost the subpopulations with intermediate vancomycin resistance, whereas two revertants maintained them. Furthermore, although all of the parent GISA isolates produced capsule type 5 (CP5), all but one revertant tested no longer produced CP5. In contrast, passage on medium containing vancomycin yielded isolates that were still intermediately resistant to vancomycin, had no decrease in the MIC of teicoplanin, and produced detectable CP5. No consistent changes in the revertants in hemolysis phenotype, lysostaphin susceptibility, or coagulase activities were discerned. These data indicate that the vancomycin resistance phenotype is unstable in clinical GISA isolates. Reversion of the vancomycin resistance phenotype might explain the difficulty in isolating vancomycin-resistant clinical isolates from the blood of patients who fail vancomycin therapy and, possibly, may account for some of the difficulties in identifying GISA isolates in the clinical laboratory.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/aac.44.2.272-277.2000

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 121

Metadata

Authors
Boyle-Vavra, S., Berke, S. K., Lee, J. C., & Daum, R. S.
Venue
Antimicrobial Agents and Chemotherapy
Published
2000-02
Volume
44
Issue
2
Pages
272-277
ISSN
  • 0066-4804 (ISSN-L)
  • 1098-6596
OpenAlex
W2121952186
Cited by
121
References
3
FWCI
10.09
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.