The DOI matches its Crossref record.
Revisiting with a Relative-Density Calibration Approach the Determination of Growth Rates of Microorganisms by Use of Optical Density Data from Liquid Cultures
Abstract
To solve the problems of measuring the growth rates of microorganisms from optical density (OD)-growth time plots, we used relative-density (RD) plots. The relationship of OD and RD was built from the diluted grown cultures. This method was satisfactorily applied to study the growth of Escherichia coli and the cyanobacterium Anabaena spiroides .
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Based on the previous report [15], the relative density method appears more applicable to cultures that grow relatively slowly, with the exponential phase lasting several hours or longer.”
From Rapid growth rate of Enterobacter sp. SM3 determined using several methods (2024) · cites this paper as [15]
In the citing paper
“Note in this method the absolute density of cells is not needed to determine the growth rate or doubling time; the relative density values suffice [15].”
From Rapid growth rate of Enterobacter sp. SM3 determined using several methods (2024) · cites this paper as [15]
In the citing paper
“Another modified approach to the optical density measurement is the relative density method [15], which can yield bacterial doubling time even if the OD readings deviate from their proportional relationship with cell density.”
From Rapid growth rate of Enterobacter sp. SM3 determined using several methods (2024) · cites this paper as [15]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 6
- 10.1128/AEM.65.2.732-736.1999 · doi:10.1128/aem.65.2.732-736.1999
- 10.1016/S0167-7012(00)00219-0 · DOI · Paper page
- Eisenberg, D., and D. Crothers. 1979. Physical chemistry with applications to the life sciences, p. 516-589. Benjamin Cummings, Menlo Park, CA.
- Lawrence, J. V., and S. Maier. 1977. Correction for the inherent error in optical density readings. Appl. Environ. Microbiol.33:3.
- 10.1128/AEM.00251-06 · DOI
- Tinoco, I. J., K. Sauer, and J. C. Wang. 1995. Physical chemistry: principles and applications in biological sciences, 3rd ed., p. 545-621. Prentice Hall, Upper Saddle River, NJ.
Cited by
Improving accuracy of cell and chromophore concentration measurements using optical density
Myers, J. A., Curtis, B. S., & Curtis, W. R. (2013) · BMC Biophysics · doi:10.1186/2046-1682-6-4 · Cited by 391
Rapid growth rate of Enterobacter sp. SM3 determined using several methods
Pollack-Milgate, S., Saitia, S., & Tang, J. X. (2024) · BMC Microbiology · doi:10.1186/s12866-024-03547-3 · Cited by 9
Metadata
- Authors
- Lin, H.-L., Lin, C.-C., Lin, Y.-J., Lin, H.-C., Shih, C.-M., Chen, C.-R., Huang, R.-N., & Kuo, T.-C.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2010-03
- Volume
- 76
- Issue
- 5
- Pages
- 1683-1685
- ISSN
- 0099-2240
- 1098-5336
- Cited by
- 34
- References
- 0
- Language
- en
- Licence
- journals.asm.org/non-commercial-tdm-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Revisiting with a Relative-Density Calibration Approach the Determination of Growth Rates of Microorganisms by Use of Optical Density Data from Liquid Cultures. https://app.cochat.ai/papers/10.1128/aem.00824-09
- The paper
- Lin, H.-L., Lin, C.-C., Lin, Y.-J., Lin, H.-C., Shih, C.-M., Chen, C.-R., Huang, R.-N., & Kuo, T.-C. (2010). Revisiting with a Relative-Density Calibration Approach the Determination of Growth Rates of Microorganisms by Use of Optical Density Data from Liquid Cultures. Applied and Environmental Microbiology. https://doi.org/10.1128/aem.00824-09
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.