The DOI matches its Crossref record.
New Electropositive Filter for Concentrating Enteroviruses and Noroviruses from Large Volumes of Water
Open accessAbstract
The U.S. Environmental Protection Agency's information collection rule requires the use of 1MDS electropositive filters for concentrating enteric viruses from water, but unfortunately, these filters are not cost-effective for routine viral monitoring. In this study, an inexpensive electropositive cartridge filter, the NanoCeram filter, was evaluated for its ability to concentrate enteroviruses and noroviruses from large volumes of water. Seeded viruses were concentrated using the adsorption-elution procedure. The mean percent retention of seeded polioviruses by NanoCeram filters was 84%. To optimize the elution procedure, six protocols, each comprising two successive elutions with various lengths of filter immersion, were evaluated. The highest virus recovery (77%) was obtained by immersing the filters in beef extract for 1 minute during the first elution and for 15 min during the second elution. The recovery efficiencies of poliovirus, coxsackievirus B5, and echovirus 7 from 100-liter samples of seeded tap water were 54%, 27%, and 32%, respectively. There was no significant difference in virus recovery from tap water with a pH range of 6 to 9.5 and a water flow rate range of 5.5 liters/min to 20 liters/min. Finally, poliovirus and Norwalk virus recoveries by NanoCeram filters were compared to those by 1MDS filters, using tap water and Ohio River water. Poliovirus and Norwalk virus recoveries by NanoCeram filters from tap and river water were similar to or higher than those by the 1MDS filters. These data suggest that NanoCeram filters can be used as an inexpensive alternative to 1MDS filters for routine viral monitoring of water.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Innovations in nanotechnology for water treatment
Gehrke, I., Geiser, A., & Somborn-Schulz, A. (2015) · Nanotechnology, Science and Applications · doi:10.2147/nsa.s43773 · Cited by 649
Haramoto, E., Kitajima, M., Hata, A., Torrey, J. R., Masago, Y., Sano, D., & Katayama, H. (2018) · Water Research · doi:10.1016/j.watres.2018.02.004 · Cited by 432
Viruses in wastewater: occurrence, abundance and detection methods
Corpuz, M. V. A., Buonerba, A., Vigliotta, G., Zarra, T., Ballesteros, F., Campiglia, P., Belgiorno, V., Korshin, G., & Naddeo, V. (2020) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.140910 · Cited by 325
Advancements in microfluidics for nanoparticle separation
Salafi, T., Zeming, K. K., & Zhang, Y. (2017) · Lab on a Chip · doi:10.1039/c6lc01045h · Cited by 261
Uyaguari-Diaz, M. I., Chan, M., Chaban, B. L., Croxen, M. A., Finke, J. F., Hill, J. E., Peabody, M. A., Van Rossum, T., Suttle, C. A., Brinkman, F. S. L., et al. (2016) · Microbiome · doi:10.1186/s40168-016-0166-1 · Cited by 104
Metadata
- Authors
- Karim, M. R., Rhodes, E. R., Brinkman, N., Wymer, L., & Fout, G. S.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2009-04-15
- Volume
- 75
- Issue
- 8
- Pages
- 2393-2399
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- OpenAlex
- W1987679769
- Cited by
- 158
- References
- 0
- FWCI
- 13.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: New Electropositive Filter for Concentrating Enteroviruses and Noroviruses from Large Volumes of Water. https://app.cochat.ai/papers/10.1128/aem.00922-08
- The paper
- Karim, M. R., Rhodes, E. R., Brinkman, N., Wymer, L., & Fout, G. S. (2009). New Electropositive Filter for Concentrating Enteroviruses and Noroviruses from Large Volumes of Water. Applied and Environmental Microbiology. https://doi.org/10.1128/aem.00922-08
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.