Bacterial Cell Surface Damage Due to Centrifugal Compaction
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Centrifugal damage has been known to alter bacterial cell surface properties and interior structures, including DNA. Very few studies exist on bacterial damage caused by centrifugation because of the difficulty in relating centrifugation speed and container geometry to the damage caused. Here, we provide a simple, versatile method of analysis for describing the compaction of bacteria during centrifugation based on a proposed centrifugation coefficient, C . Values of C can be related to different bacterial cell surface properties. Changing the geometry of the centrifugation container or centrifugation speeds changed the value of C significantly. Initial deposition rates of Staphylococcus aureus ATCC 12600 to a glass surface decayed exponentially from 4,217 to 1,478 cm −2 s −1 with increasing C , while the proportion of staphylococci with a zeta potential of around −15 mV decreased from 97 to 58%. These surface-sensitive parameters were used independently to derive a critical centrifugation coefficient (0.040), above which centrifugation was considered to impact the outcome of surface-sensitive experiments due to cell surface damage. The critical centrifugation coefficient could successfully predict staphylococcal cell surface damage, i.e., a significant change in initial deposition rate or zeta potential distribution, in 84% of all cases included here, whereas the centrifugation speed could predict damage in only 58% of all cases. Moreover, controlling the centrifugation coefficient within narrow limits over a series of experiments yielded 43% smaller standard deviations in initial staphylococcal deposition rates than with centrifugation at fixed speeds for replicate experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
How Strong Is a Covalent Bond?
Grandbois, M., Beyer, M., Rief, M., Clausen-Schaumann, H., & Gaub, H. E. (1999) · Science · doi:10.1126/science.283.5408.1727 · Cited by 1,095
Microbial Adhesion in Flow Displacement Systems
Busscher, H. J., & van der Mei, H. C. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.1.127-141.2006 · Cited by 295 · cited 2×
“Initial bacterial deposition rates (j0) were determined on the bottom glass plate of the flow chamber with dimensions (3) of 17.”
MethodSelf-citationCell Surface Analysis Techniques: What Do Cell Preparation Protocols Do to Cell Surface Properties?
Pembrey, R. S., Marshall, K. C., & Schneider, R. P. (1999) · Applied and Environmental Microbiology · doi:10.1128/aem.65.7.2877-2894.1999 · Cited by 241 · cited 2×
“In general, harvesting by the high-speed centrifugation (15,000 g) of bacterial cultures was found to reduce the surface charge of organisms not protected by a dense layer of extracellular polymeric substances (9).”
BackgroundRelevance of Polymeric Matrix Enzymes During Biofilm Formation
Romaní, A. M., Fund, K., Artigas, J., Schwartz, T., Sabater, S., & Obst, U. (2008) · Microbial Ecology · doi:10.1007/s00248-007-9361-8 · Cited by 165 · cited 1×
“Many experimental protocols choose high centrifugation speeds to collect as many bacteria as possible while assuming that it does not cause any bacterial cell damage or cell death (4, 10).”
BackgroundEffects of cell surface damage on surface properties and adhesion of Pseudomonas aeruginosa
Bruinsma, G. M., Rustema‐Abbing, M., van der Mei, H. C., & Busscher, H. J. (2001) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(01)00238-x · Cited by 113 · cited 1×
“Chemical and physical surface damage to Pseudomonas aeruginosa, for instance, yielded lower initial deposition rates to substratum surfaces than were observed for undamaged bacteria (2).”
BackgroundSelf-citationBond Strengthening in Oral Bacterial Adhesion to Salivary Conditioning Films
van der Mei, H. C., Rustema‐Abbing, M., de Vries, J., & Busscher, H. J. (2008) · Applied and Environmental Microbiology · doi:10.1128/aem.01119-08 · Cited by 76
Self-citationVats, N., & Lee, S. F. (2000) · Archives of Oral Biology · doi:10.1016/s0003-9969(99)00139-9 · Cited by 45
Deupree, S. M., & Schoenfisch, M. H. (2008) · Langmuir · doi:10.1021/la800417g · Cited by 29 · cited 1×
“Many experimental protocols choose high centrifugation speeds to collect as many bacteria as possible while assuming that it does not cause any bacterial cell damage or cell death (4, 10).”
Background
Cited by
Tubbs, A., Ahmed, J. U., Christopher, J., & Alvarez, J. C. (2024) · Analytical Methods · doi:10.1039/d4ay00899e · Cited by 5
“26 The supernatant was removed and the pellet was resuspended in 1 mM PBS.”
Metadata
- Authors
- Peterson, B. W., Sharma, P. K., van der Mei, H. C., & Busscher, H. J.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2012-01
- Volume
- 78
- Issue
- 1
- Pages
- 120-125
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- OpenAlex
- W2129708328
- Cited by
- 168
- References
- 8
- FWCI
- 0.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bacterial Cell Surface Damage Due to Centrifugal Compaction. https://app.cochat.ai/papers/10.1128/aem.06780-11
- The paper
- Peterson, B. W., Sharma, P. K., van der Mei, H. C., & Busscher, H. J. (2012). Bacterial Cell Surface Damage Due to Centrifugal Compaction. Applied and Environmental Microbiology. https://doi.org/10.1128/aem.06780-11
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.