The DOI matches its Crossref record.
Comparative assessment of chlorine, heat, ozone, and UV light for killing Legionella pneumophila within a model plumbing system
Open accessAbstract
Nosocomial Legionnaires disease can be acquired by exposure to the organism from the hospital water distribution system. As a result, many hospitals have instituted eradication procedures, including hypercholorination and thermal eradication. We compared the efficacy of ozonation, UV light, hyperchlorination, and heat eradication using a model plumbing system constructed of copper piping, brass spigots, Plexiglas reservoir, electric hot water tank, and a pump. Legionella pneumophila was added to the system at 10(7) CFU/ml. Each method was tested under three conditions; (i) nonturbid water at 25 degrees C, (ii) turbid water at 25 degrees C, and (iii) nonturbid water at 43 degrees C. UV light and heat killed L. pneumophila most rapidly and required minimal maintenance. Both UV light and heat (60 degrees C) produced a 5 log kill in less than 1 h. In contrast, both chlorine and ozone required 5 h of exposure to produce a 5 log decrease. Neither turbidity nor the higher temperature of 43 degrees C impaired the efficacy of any of the disinfectant methods. Surprisingly, higher temperature enhanced the disinfecting efficacy of chlorine. However, higher temperature accelerated the decomposition of the chlorine residual such that an additional 120% volume of chlorine was required. All four methods proved efficacious in eradicating L. pneumophila from a model plumbing system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Amoebae as Training Grounds for Intracellular Bacterial Pathogens
Molmeret, M., Horn, M., Wagner, M., Santic, M., & Abu Kwaik, Y. (2005) · Applied and Environmental Microbiology · doi:10.1128/aem.71.1.20-28.2005 · Cited by 555
Uses of inorganic hypochlorite (bleach) in health-care facilities
Rutala, W. A., & Weber, D. J. (1997) · Clinical Microbiology Reviews · doi:10.1128/cmr.10.4.597 · Cited by 523
Guideline for Prevention of Nosocomial Pneumonia
Tablan, O. C., Anderson, L. J., Arden, N. H., Breiman, R. F., Butler, J. C., McNeil, M. M., & The Hospital Infection Control Practices Advisory Committee (1994) · Infection Control and Hospital Epidemiology · doi:10.2307/30147436 · Cited by 500
Sedlak, D. L., & von Gunten, U. (2011) · Science · doi:10.1126/science.1196397 · Cited by 437
Metadata
- Authors
- Muraca, P., Stout, J. E., & Yu, V. L.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1987-02
- Volume
- 53
- Issue
- 2
- Pages
- 447-453
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- OpenAlex
- W1516157366
- Cited by
- 165
- References
- 0
- FWCI
- 2.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparative assessment of chlorine, heat, ozone, and UV light for killing Legionella pneumophila within a model plumbing system. https://app.cochat.ai/papers/10.1128/aem.53.2.447-453.1987
- The paper
- Muraca, P., Stout, J. E., & Yu, V. L. (1987). Comparative assessment of chlorine, heat, ozone, and UV light for killing Legionella pneumophila within a model plumbing system. Applied and Environmental Microbiology. https://doi.org/10.1128/aem.53.2.447-453.1987
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.