Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 252

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Legionella contamination of dental-unit waters

Open access
Atlas, R M, Williams, J F, Huntington, M K · 1995 · Applied and Environmental Microbiology

Abstract

Water samples collected from 28 dental facilities in six U.S. states were examined for the presence of Legionella pneumophila and other Legionella spp. by the PCR-gene probe, fluorescent-antibody microscopic, and viable-plate-count detection methods. The PCR and fluorescent-antibody detection methods, which detect both viable and viable nonculturable Legionella spp., gave higher counts and rates of detection than the plate count method. By the PCR-gene probe detection method, Legionella spp. were detected in 68% of the dental-unit water samples and L. pneumophila was detected in 8%. Concentrations of Legionella spp. in dental-unit water reached 1,000 organisms per ml or more in 36% of the samples, and 19% of the samples were in the category of 10,000/ml or above. L. pneumophila, when present in dental-unit water, never reached concentrations of 1,000/ml or more. Microscopic examination with fluorescent-antibody staining indicated that the contamination was in the dental-unit water lines rather than in the handpieces. Legionella spp. were present in 61% of potable water samples collected for comparative analysis from domestic and institutional faucets and drinking fountains; this percentage was not significantly different from the rate of detection of Legionella spp. in dental-unit water. However, in only 4% of the potable water samples did Legionella spp. reach concentrations of 1,000 organisms per ml, and none was in the 10,000 organisms-per-ml category, and so health-threatening levels of Legionella spp. in potable water were significantly lower than in dental-unit water. L. pneumophila was found in 2% of the potable water samples, but only at the lowest detectable level.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/aem.61.4.1208-1213.1995

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 252

Metadata

Authors
Atlas, R. M., Williams, J. F., & Huntington, M. K.
Venue
Applied and Environmental Microbiology
Published
1995-04
Volume
61
Issue
4
Pages
1208-1213
ISSN
  • 0099-2240 (ISSN-L)
  • 1098-5336
OpenAlex
W2108833754
Cited by
252
References
8
FWCI
3.99
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Legionella contamination of dental-unit waters. https://app.cochat.ai/papers/10.1128/aem.61.4.1208-1213.1995
The paper
Atlas, R. M., Williams, J. F., & Huntington, M. K. (1995). Legionella contamination of dental-unit waters. Applied and Environmental Microbiology. https://doi.org/10.1128/aem.61.4.1208-1213.1995

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.