CoChat

Measurement of beta(1-->3)-glucans in occupational and home environments with an inhibition enzyme immunoassay

Open access
Douwes, J, Doekes, G, Montijn, R, Heederik, D, Brunekreef, B · 1996 · Applied and Environmental Microbiology
Cited by 133

The DOI matches its Crossref record.

Abstract

beta (1-->3)-Glucans are known for their potent ability to induce nonspecific inflammatory reactions and are believed to play a role in bioaerosol-induced respiratory symptoms. An inhibition enzyme immunoassay (EIA) was developed for the quantitation of beta (1-->3)-glucans in dust samples from occupational and residential environments. Immunospecific rabbit antibodies were produced by immunization with bovine serum albumin-conjugated laminarin [beta (1-->3)-glucan] and affinity chromatography on epoxy-Sepharose-coupled beta (1-->3)-glucans. The laminarin-based calibration curve in the inhibition EIA ranged from approximately 40 to 3,000 ng/ml (15 to 85% inhibition). Another beta (1-->3)-glucan (curdlan) showed a similar inhibition curve but was three to five times less reactive on a weight basis. Pustulan, presumed to be a beta (1-->6)-glucan, showed a parallel dose-response curve at concentrations 10 times higher than that of laminarin. Control experiments with NaIO4 and beta (1-->3)-glucanase treatment to destroy beta (1-->6)- and beta (1-->3)-glucan structures, respectively, indicate that the immunoreactivity of pustulan in the assay was due to beta (1-->3)-glucan and not to beta (1-->6)-glucan structures. Other polysaccharides, such as mannan and alpha (1-->6)-glucan, did not react in the inhibition EIA. Beta (1-->3)-Glucan extraction of dust samples in water (with mild detergent) was performed by heat treatment (120 degrees C) because aqueous extracts obtained at room temperature did not contain detectable beta (1-->3)-glucan levels. The assay was shown to detect heat-extractable beta (1-->3)-glucan in dust samples collected in a variety of occupational and environmental settings. On the basis of duplicate analyses of dust samples, a coefficient of variation of approximately 25% was calculated. It was concluded that the new inhibition EIA offers a useful method for indoor beta (1-->3)-glucan exposure assessment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/aem.62.9.3176-3182.1996

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 133

Metadata

Authors
Douwes, J., Doekes, G., Montijn, R., Heederik, D., & Brunekreef, B.
Venue
Applied and Environmental Microbiology
Published
1996-09
Volume
62
Issue
9
Pages
3176-3182
ISSN
  • 0099-2240 (ISSN-L)
  • 1098-5336
OpenAlex
W1479913097
Cited by
133
References
0
FWCI
4.16
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of beta(1-->3)-glucans in occupational and home environments with an inhibition enzyme immunoassay. https://app.cochat.ai/papers/10.1128/aem.62.9.3176-3182.1996
The paper
Douwes, J., Doekes, G., Montijn, R., Heederik, D., & Brunekreef, B. (1996). Measurement of beta(1-->3)-glucans in occupational and home environments with an inhibition enzyme immunoassay. Applied and Environmental Microbiology. https://doi.org/10.1128/aem.62.9.3176-3182.1996

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.