The DOI matches its Crossref record.
Automated Confocal Laser Scanning Microscopy and Semiautomated Image Processing for Analysis of Biofilms
Open accessAbstract
The purpose of this study was to develop and apply a quantitative optical method suitable for routine measurements of biofilm structures under in situ conditions. A computer program was designed to perform automated investigations of biofilms by using image acquisition and image analysis techniques. To obtain a representative profile of a growing biofilm, a nondestructive procedure was created to study and quantify undisturbed microbial populations within the physical environment of a glass flow cell. Key components of the computer-controlled processing described in this paper are the on-line collection of confocal two-dimensional (2D) cross-sectional images from a preset 3D domain of interest followed by the off-line analysis of these 2D images. With the quantitative extraction of information contained in each image, a three-dimensional reconstruction of the principal biological events can be achieved. The program is convenient to handle and was generated to determine biovolumes and thus facilitate the examination of dynamic processes within biofilms. In the present study, Pseudomonas fluorescens or a green fluorescent protein-expressing Escherichia coli strain, EC12, was inoculated into glass flow cells and the respective monoculture biofilms were analyzed in three dimensions. In this paper we describe a method for the routine measurements of biofilms by using automated image acquisition and semiautomated image analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quantification of biofilm structures by the novel computer program comstat
Heydorn, A., Nielsen, A. T., Hentzer, M., Sternberg, C., Givskov, M., Ersbøll, B. K., & Molin, S. (2000) · Microbiology · doi:10.1099/00221287-146-10-2395 · Cited by 2,179
Molin, S., & Tolker-Nielsen, T. (2003) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(03)00036-3 · Cited by 708
daime , a novel image analysis program for microbial ecology and biofilm research
Daims, H., Lücker, S., & Wagner, M. (2006) · Environmental Microbiology · doi:10.1111/j.1462-2920.2005.00880.x · Cited by 579
Self-citationNew frontiers for the materials genome initiative
de Pablo, J. J., Jackson, N. E., Webb, M. A., Chen, L.-Q., Moore, J. E., Morgan, D., Jacobs, R., Pollock, T., Schlom, D. G., Toberer, E. S., et al. (2019) · npj Computational Materials · doi:10.1038/s41524-019-0173-4 · Cited by 562
High Rates of Conjugation in Bacterial Biofilms as Determined by Quantitative In Situ Analysis
Hausner, M., & Wuertz, S. (1999) · Applied and Environmental Microbiology · doi:10.1128/aem.65.8.3710-3713.1999 · Cited by 486
Self-citation
Metadata
- Authors
- Kuehn, M., Hausner, M., Bungartz, H.-J., Wagner, M., Wilderer, P. A., & Wuertz, S.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1998-11
- Volume
- 64
- Issue
- 11
- Pages
- 4115-4127
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- OpenAlex
- W1873450334
- Cited by
- 163
- References
- 0
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated Confocal Laser Scanning Microscopy and Semiautomated Image Processing for Analysis of Biofilms. https://app.cochat.ai/papers/10.1128/aem.64.11.4115-4127.1998
- The paper
- Kuehn, M., Hausner, M., Bungartz, H.-J., Wagner, M., Wilderer, P. A., & Wuertz, S. (1998). Automated Confocal Laser Scanning Microscopy and Semiautomated Image Processing for Analysis of Biofilms. Applied and Environmental Microbiology. https://doi.org/10.1128/aem.64.11.4115-4127.1998
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.