The DOI matches its Crossref record.
Influence of Temperature and Pressure on the Lethality of Ultrasound
Open accessAbstract
A specially designed resistometer was constructed, and the lethal effect on Yersinia enterocolitica of ultrasonic waves (UW) at different static pressures (manosonication [MS]) and of combined heat-UW under pressure treatments (manothermosonication [MTS]) was investigated. During MS treatments at 30°C and 200 kPa, the increase in the amplitude of UW of 20 kHz from 21 to 150 μm exponentially decreased decimal reduction time values ( D MS ) from 4 to 0.37 min. When pressure was increased from 0 to 600 kPa at a constant amplitude (150 μm) and temperature (30°C), D MS values decreased from 1.52 to 0.20 min. The magnitude of this decrease in D MS declined progressively as pressure was increased. The influence of pressure on D MS values was greater with increased amplitude of UW. Pressure alone of as much as 600 kPa did not influence the heat resistance of Y. enterocolitica ( D 60 = 0.094; z = 5.65). At temperatures of as much as 58°C, the lethality of UW under pressure was greater than that of heat treatment alone at the same temperature. At higher temperatures, this difference disappeared. Heat and UW under pressure seemed to act independently. The lethality of MTS treatments appeared to result from the added effects of UW under pressure and the lethal effect of heat. The individual contributions of heat and of UW under pressure to the total lethal effect of MTS depended on temperature. The inactivating effect of UW was not due to titanium particles eroded from the sonication horn. The addition to the MS media of cysteamine did not increase the resistance of Y. enterocolitica to MS treatment. MS treatment caused cell disruption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Applications of ultrasound in analysis, processing and quality control of food: A review
Awad, T. S., Moharram, H. A., Shaltout, O. E., Asker, D., & Youssef, M. M. (2012) · Food Research International · doi:10.1016/j.foodres.2012.05.004 · Cited by 996
Inactivation of microbes using ultrasound: a review
Piyasena, P., Mohareb, E., & McKellar, R. C. (2003) · International Journal of Food Microbiology · doi:10.1016/s0168-1605(03)00075-8 · Cited by 886
Emerging technologies: chemical aspects
Butz, P., & Tauscher, B. (2002) · Food Research International · doi:10.1016/s0963-9969(01)00197-1 · Cited by 496
Reverse osmosis pretreatment technologies and future trends: A comprehensive review
Anis, S. F., Hashaikeh, R., & Hilal, N. (2019) · Desalination · doi:10.1016/j.desal.2018.11.006 · Cited by 495
Microbial inactivation by new technologies of food preservation
Mañas, P., & Pagán, R. (2005) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2005.02561.x · Cited by 440
Metadata
- Authors
- Raso, J., Pagán, R., Condón, S., & Sala, F. J.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1998-02
- Volume
- 64
- Issue
- 2
- Pages
- 465-471
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- OpenAlex
- W1543171182
- Cited by
- 236
- References
- 0
- FWCI
- 7.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of Temperature and Pressure on the Lethality of Ultrasound. https://app.cochat.ai/papers/10.1128/aem.64.2.465-471.1998
- The paper
- Raso, J., Pagán, R., Condón, S., & Sala, F. J. (1998). Influence of Temperature and Pressure on the Lethality of Ultrasound. Applied and Environmental Microbiology. https://doi.org/10.1128/aem.64.2.465-471.1998
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.