Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 348

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Standardization of an opsonophagocytic assay for the measurement of functional antibody activity against Streptococcus pneumoniae using differentiated HL-60 cells

Open access
Romero-Steiner, S, Libutti, D, Pais, L B, Dykes, J, Anderson, P, Whitin, J C, Keyserling, H L, Carlone, G M·1997·Clinical Diagnostic Laboratory Immunology

Abstract

Host protection against pneumococcal disease i primarily mediated by phagocytosis. We developed and standardized an opsonophagocytic assay using HL-60 cells (human promyelocytic leukemia cells). Fifty-five serum samples were analyzed for the presence of functional antibody against seven pneumococcal serogroups or serotypes (4, 6B, 9V, 14, 18C, 19F, and 23F) by using differentiated HL-60 cells (granulocytes) and peripheral blood leukocytes (PBLs). Six of the 55 serum samples were from unvaccinated adult volunteers, 31 serum samples were from adults who received one dose of the 14-valent or the 23-valent polysaccharide vaccine, and 18 serum samples were from 16-month-old infants who received four doses of an investigational 7-valent polysaccharide-protein conjugate vaccine. The results of an opsonophagocytic assay with HL-60 cells correlated highly with those of an assay with PBLs as effector cells (median r for seven serotypes = 0.87: P < 0.01). Opsonophagocytic titers were compared with the immunoglobulin G antibody concentrations determined by enzyme-linked immunosorbent assay (ELISA). The r values for serogroups or serotypes 4, 6B, 9V, 14, 18C, 19F, and 23F were 0.61, 0.60, 0.67 0.90, 0.61, 0.39, and 0.57, respectively, when HL-60 cells were used as effector cells and 0.56, 0.47, 0.61, 0.90, 0.71, 0.31, and 0.62, respectively, when PBLs were used. The assay requires small amounts of serum (40 microliters per serotype), making this test suitable for assaying infant sera. Culturable cells aid in assay standardization and likely reduce donor-to-donor variability. This standardized assay, in combination with the standardized ELISA, can be used to evaluate current and developing pneumococcal vaccines, in which functional opsonophagocytic antibody activity may correlate with protection against pneumococcal disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/cdli.4.4.415-422.1997

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 348

Metadata

Authors
Romero-Steiner, S., Libutti, D., Pais, L. B., Dykes, J., Anderson, P., Whitin, J. C., Keyserling, H. L., & Carlone, G. M.
Venue
Clinical Diagnostic Laboratory Immunology
Published
1997-07
Volume
4
Issue
4
Pages
415-422
ISSN
  • 1071-412X (ISSN-L)
  • 1098-6588
OpenAlex
W2128173146
Cited by
348
References
25
FWCI
7.61
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Standardization of an opsonophagocytic assay for the measurement of functional antibody activity against Streptococcus pneumoniae using differentiated HL-60 cells. https://app.cochat.ai/papers/10.1128/cdli.4.4.415-422.1997
The paper
Romero-Steiner, S., Libutti, D., Pais, L. B., Dykes, J., Anderson, P., Whitin, J. C., Keyserling, H. L., & Carlone, G. M. (1997). Standardization of an opsonophagocytic assay for the measurement of functional antibody activity against Streptococcus pneumoniae using differentiated HL-60 cells. Clinical Diagnostic Laboratory Immunology. https://doi.org/10.1128/cdli.4.4.415-422.1997

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.