The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Multiplex, Bead-Based Suspension Array for Molecular Determination of Common Salmonella Serogroups
Open accessAbstract
We report the development and evaluation of a Salmonella O-group-specific Bio-Plex assay to detect the six most common serogroups in the United States (B, C 1 , C 2 , D, E, and O13) plus serotype Paratyphi A. The assay is based on rfb gene targets directly involved in O-antigen biosynthesis; it can be completed 45 min post-PCR amplification. The assay correctly and specifically identified 362 of 384 (94.3%) isolates tested in comparison to traditional serotyping. Seventeen isolates (4.4%) produced results consistent with what is known about the molecular basis for serotypes but different from the results of traditional serotyping, and five isolates (1.3%) generated false-negative results. Molecular determination of the serogroup for rough isolates was consistent with a common serotype in most instances, indicating that this approach has the potential to provide O-group information for isolates that do not express an O antigen. We also report the sequence of the O-antigen-encoding rfb gene cluster from Salmonella enterica serotype Poona (serogroup O13). Compared with other, previously characterized rfb regions, the O13 rfb gene cluster was most closely related to Escherichia coli O127 and O86. The O-group Bio-Plex assay described here provides an easy-to-use, high-throughput system for rapid detection of common Salmonella serogroups.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McClelland, M., Sanderson, K. E., Clifton, S. W., Latreille, P., Porwollik, S., Sabo, A., Meyer, R., Bieri, T., Ozersky, P., McLellan, M., et al. (2004) · Nature Genetics · doi:10.1038/ng1470 · Cited by 391
Cited by
Multilocus sequence typing as a replacement for serotyping in Salmonella enterica
Achtman, M., Wain, J., Weill, F.-X., Nair, S., Zhou, Z., Sangal, V., Krauland, M. G., Hale, J. L., Harbottle, H., Uesbeck, A., et al. (2012) · PLoS Pathogens · doi:10.1371/journal.ppat.1002776 · Cited by 710
Yoshida, C. E., Kruczkiewicz, P., Laing, C. R., Lingohr, E. J., Gannon, V. P. J., Nash, J. H. E., & Taboada, E. N. (2016) · PLOS ONE · doi:10.1371/journal.pone.0147101 · Cited by 597
Salmonella Serotype Determination Utilizing High-Throughput Genome Sequencing Data
Zhang, S., Yin, Y., Jones, M. B., Zhang, Z., Deatherage Kaiser, B. L., Dinsmore, B. A., Fitzgerald, C., Fields, P. I., & Deng, X. (2015) · Journal of Clinical Microbiology · doi:10.1128/jcm.00323-15 · Cited by 423
Self-citationBasic Concepts of Microarrays and Potential Applications in Clinical Microbiology
Miller, M. B., & Tang, Y.-W. (2009) · Clinical Microbiology Reviews · doi:10.1128/cmr.00019-09 · Cited by 419
SeqSero2: Rapid and Improved Salmonella Serotype Determination Using Whole-Genome Sequencing Data
Zhang, S., den Bakker, H. C., Li, S., Chen, J., Dinsmore, B. A., Lane, C., Lauer, A. C., Fields, P. I., & Deng, X. (2019) · Applied and Environmental Microbiology · doi:10.1128/aem.01746-19 · Cited by 366
Self-citation
Metadata
- Authors
- Fitzgerald, C., Collins, M., van Duyne, S., Mikoleit, M., Brown, T., & Fields, P.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2007-10
- Volume
- 45
- Issue
- 10
- Pages
- 3323-3334
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2145825014
- Cited by
- 160
- References
- 1
- FWCI
- 14.41
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiplex, Bead-Based Suspension Array for Molecular Determination of Common Salmonella Serogroups. https://app.cochat.ai/papers/10.1128/jcm.00025-07
- The paper
- Fitzgerald, C., Collins, M., van Duyne, S., Mikoleit, M., Brown, T., & Fields, P. (2007). Multiplex, Bead-Based Suspension Array for Molecular Determination of Common Salmonella Serogroups. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.00025-07
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.