CoChat

Cerebrospinal Fluid Treponema pallidum Particle Agglutination Assay for Neurosyphilis Diagnosis

Open access
Marra, Christina M., Maxwell, Clare L., Dunaway, Shelia B., Sahi, Sharon K., Tantalo, Lauren C. · 2017 · Journal of Clinical Microbiology
Cited by 92

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Limited data suggest that the cerebrospinal fluid Treponema pallidum particle agglutination assay (CSF-TPPA) is sensitive and a CSF Treponema pallidum hemagglutination assay (CSF-TPHA) titer of ≥1:640 is specific for neurosyphilis diagnosis. CSF-TPPA reactivity and titer were determined for a convenience sample of 191 CSF samples from individuals enrolled in a study of CSF abnormalities in syphilis (training data set). The sensitivity of a reactive test and the specificity for reactivity at serial higher CSF dilutions were determined. Subsequently, CSF-TPPA reactivity at a 1:640 dilution was determined for all available samples from study participants enrolled after the last training sample was collected (validation data set, n = 380). Neurosyphilis was defined as (i) a reactive CSF Venereal Disease Research Laboratory test (CSF-VDRL), (ii) detection of T. pallidum in CSF by reverse transcriptase PCR, or (iii) new vision loss or hearing loss. In the training data set, the diagnostic sensitivities of a reactive CSF fluorescent treponemal antibody absorption test (CSF-FTA-ABS) and a reactive CSF-TPPA did not differ significantly (67 to 98% versus 76 to 95%). The specificity of a CSF-TPPA titer of ≥1:640 was significantly higher than that of lower dilutions and was not significantly different from that of CSF-VDRL. In the validation data set, the diagnostic specificity of a CSF-TPPA titer of ≥1:640 was high and did not differ significantly from that of CSF-VDRL (93 to 94% versus 90 to 91%). Ten CSF samples with a nonreactive CSF-VDRL had a CSF-TPPA titer of ≥1:640. If a CSF-TPPA titer of ≥1:640 was used in addition to a reactive CSF-VDRL, the number of neurosyphilis diagnoses would have increased from 47 to 57 (21.3%). A CSF-TPPA titer cutoff of ≥1:640 may be useful in identifying patients with neurosyphilis when CSF-VDRL is nonreactive.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.00310-17

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 92

Metadata

Authors
Marra, C. M., Maxwell, C. L., Dunaway, S. B., Sahi, S. K., & Tantalo, L. C.
Venue
Journal of Clinical Microbiology
Published
2017-06
Volume
55
Issue
6
Pages
1865-1870
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2605293614
Cited by
92
References
7
FWCI
2.92
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cerebrospinal Fluid Treponema pallidum Particle Agglutination Assay for Neurosyphilis Diagnosis. https://app.cochat.ai/papers/10.1128/jcm.00310-17
The paper
Marra, C. M., Maxwell, C. L., Dunaway, S. B., Sahi, S. K., & Tantalo, L. C. (2017). Cerebrospinal Fluid Treponema pallidum Particle Agglutination Assay for Neurosyphilis Diagnosis. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.00310-17

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.