CoChat

Comparison of Detection Methods for Heteroresistant Vancomycin-Intermediate Staphylococcus aureus , with the Population Analysis Profile Method as the Reference Method

Open access
Satola, Sarah W., Farley, Monica M., Anderson, Karen F., Patel, Jean B. · 2011 · Journal of Clinical Microbiology
Cited by 143

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Staphylococcus aureus clinical isolates with vancomycin MICs of 2 μg/ml have been associated with vancomycin therapeutic failure and the heteroresistant vancomycin-intermediate S. aureus (hVISA) phenotype. A population analysis profile (PAP) with an area under the curve (AUC) ratio of ≥0.9 for the AUC of the clinical isolate versus the AUC for hVISA strain Mu3 is most often used for determining hVISA, but it is time-consuming and labor-intensive. A collection of 140 MRSA blood isolates with vancomycin MICs of 2 μg/ml by reference broth microdilution and screened for hVISA using PAP-AUC (21/140 [15%] hVISA) were tested by additional methods to detect hVISA. The methods included (i) Etest macromethod using vancomycin and teicoplanin test strips, brain heart infusion (BHI) agar, and a 2.0 McFarland inoculum; (ii) Etest glycopeptide resistance detection (GRD) using vancomycin-teicoplanin double-sided gradient test strips on Mueller-Hinton agar (MHA) with 5% sheep blood and a 0.5 McFarland inoculum; and (iii) BHI screen agar plates containing 4 μg/ml vancomycin and 16 g/liter casein using 0.5 and 2.0 McFarland inocula. Each method was evaluated using PAP-AUC as the reference method. The sensitivity of each method for detecting hVISA was higher when the results were read at 48 h. The Etest macromethod was 57% sensitive and 96% specific, Etest GRD was 57% sensitive and 97% specific, and BHI screen agar was 90% sensitive and 95% specific with a 0.5 McFarland inoculum and 100% sensitive and 68% specific with a 2.0 McFarland inoculum. BHI screen agar with 4 μg/ml vancomycin and casein and a 0.5 McFarland inoculum had the best sensitivity and specificity combination, was easy to perform, and may be useful for clinical detection of hVISA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.01128-10

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 143

Metadata

Authors
Satola, S. W., Farley, M. M., Anderson, K. F., & Patel, J. B.
Venue
Journal of Clinical Microbiology
Published
2011-01
Volume
49
Issue
1
Pages
177-183
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2097650553
Cited by
143
References
2
FWCI
4.42
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.