Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 163

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Use of the Accelerate Pheno System for Identification and Antimicrobial Susceptibility Testing of Pathogens in Positive Blood Cultures and Impact on Time to Results and Workflow

Open access
Charnot-Katsikas, Angella, Tesic, Vera, Love, Nedra, Hill, Brandy, Bethel, Cindy, Boonlayangoor, Sue, Beavis, Kathleen G.·2018·Journal of Clinical Microbiology

Abstract

The Accelerate Pheno system uses automated fluorescence in situ hybridization technology with morphokinetic cellular analysis to provide rapid species identification (ID) and antimicrobial susceptibility testing (AST) results for the most commonly identified organisms in bloodstream infections. The objective was to evaluate the accuracy and workflow of bacterial and yeast ID and bacterial AST using the Accelerate Pheno system in the clinical microbiology laboratory. The consecutive fresh blood cultures received in the laboratory were analyzed by the Accelerate Pheno system within 0 to 8 h of growth detection. ID/AST performance, the average times to results, and workflow were compared to those of the routine standard of care. Of the 232 blood cultures evaluated (223 monomicrobial and 9 polymicrobial) comprising 241 organisms, the overall sensitivity and specificity for the identification of organisms were 95.6% and 99.5%, respectively. For antimicrobial susceptibility, the overall essential agreement was 95.1% and categorical agreement was 95.5% compared to routine methods. There was one very major error and 3 major errors. The time to identification and the time to susceptibility using the Accelerate Pheno system were decreased by 23.47 and 41.86 h, respectively, compared to those for the standard of care. The reduction in hands on time was 25.5 min per culture. The Accelerate Pheno system provides rapid and accurate ID/AST results for most of the organisms found routinely in blood cultures. It is easy to use, reduces hands on time for ID/AST of common blood pathogens, and enables clinically actionable results to be released much earlier than with the current standard of care.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.01166-17

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 163

Metadata

Authors
Charnot-Katsikas, A., Tesic, V., Love, N., Hill, B., Bethel, C., Boonlayangoor, S., & Beavis, K. G.
Venue
Journal of Clinical Microbiology
Published
2018-01
Volume
56
Issue
1
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2767359853
Cited by
163
References
4
FWCI
13.45
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of the Accelerate Pheno System for Identification and Antimicrobial Susceptibility Testing of Pathogens in Positive Blood Cultures and Impact on Time to Results and Workflow. https://app.cochat.ai/papers/10.1128/jcm.01166-17
The paper
Charnot-Katsikas, A., Tesic, V., Love, N., Hill, B., Bethel, C., Boonlayangoor, S., & Beavis, K. G. (2018). Use of the Accelerate Pheno System for Identification and Antimicrobial Susceptibility Testing of Pathogens in Positive Blood Cultures and Impact on Time to Results and Workflow. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.01166-17

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.