The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Evaluation of Quantitative Analysis of Cultures from Sonicated Retrieved Orthopedic Implants in Diagnosis of Orthopedic Infection
Open accessAbstract
To improve the microbiological diagnosis of device-related osteoarticular infections, we have developed a protocol based on the sonication of device samples, followed by concentration and inoculation of the sonicate in a broad variety of media in a quantitative manner. Sixty-six samples from 31 patients were included in the study (17 of them with clinical diagnosis of infection). The sonication procedure had a sensitivity of 94.1%, which is better than that of conventional cultures (88.2%). One case of contamination and six cases of unexpected positive cultures were detected (specificity of 42.8%): two of these were considered to represent true infection, while the other four were considered to be nonsignificant (corrected specificity of 50%), although the clinical importance of these isolates is questionable. When we analyzed the number of CFU, no breakpoint between significant and nonsignificant isolates could be established. Based on our results, the procedure of sonication of retrieved implants is better than conventional cultures for the diagnosis of device-related infections. The significance of some isolates in patients without clinical infection remains uncertain. However, they may become pathogens and cannot be routinely considered to be contamination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biofilms: Survival Mechanisms of Clinically Relevant Microorganisms
Donlan, R. M., & Costerton, J. W. (2002) · Clinical Microbiology Reviews · doi:10.1128/cmr.15.2.167-193.2002 · Cited by 6,644
Persistent and Relapsing Infections Associated with Small-Colony Variants of Staphylococcus aureus
Proctor, R. A., van Langevelde, P., Kristjansson, M., Maslow, J. N., & Arbeit, R. D. (1995) · Clinical Infectious Diseases · doi:10.1093/clinids/20.1.95 · Cited by 437
Cited by
Tande, A. J., & Patel, R. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00111-13 · Cited by 1,885
Infection Associated with Prosthetic Joints
Del Pozo, J. L., & Patel, R. (2009) · New England Journal of Medicine · doi:10.1056/nejmcp0905029 · Cited by 816
Microbiologic Diagnosis of Prosthetic Shoulder Infection by Use of Implant Sonication
Piper, K. E., Jacobson, M. J., Cofield, R. H., Sperling, J. W., Sanchez-Sotelo, J., Osmon, D. R., McDowell, A., Patrick, S., Steckelberg, J. M., Mandrekar, J. N., et al. (2009) · Journal of Clinical Microbiology · doi:10.1128/jcm.01686-08 · Cited by 418
The role of microbial biofilms in prosthetic joint infections: A review
Gbejuade, H. O., Lovering, A. M., & Webb, J. C. (2015) · Acta Orthopaedica · doi:10.3109/17453674.2014.966290 · Cited by 418
Metadata
- Authors
- Esteban, J., Gomez-Barrena, E., Cordero, J., Martín-de-Hijas, N. Z., Kinnari, T. J., & Fernandez-Roblas, R.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2008-02
- Volume
- 46
- Issue
- 2
- Pages
- 488-492
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2107617138
- Cited by
- 169
- References
- 2
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Quantitative Analysis of Cultures from Sonicated Retrieved Orthopedic Implants in Diagnosis of Orthopedic Infection. https://app.cochat.ai/papers/10.1128/jcm.01762-07
- The paper
- Esteban, J., Gomez-Barrena, E., Cordero, J., Martín-de-Hijas, N. Z., Kinnari, T. J., & Fernandez-Roblas, R. (2008). Evaluation of Quantitative Analysis of Cultures from Sonicated Retrieved Orthopedic Implants in Diagnosis of Orthopedic Infection. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.01762-07
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.