Evaluation of the Xpert Methicillin-Resistant Staphylococcus aureus (MRSA) Assay Using the GeneXpert Real-Time PCR Platform for Rapid Detection of MRSA from Screening Specimens
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The need for rapid methods to accurately detect methicillin-resistant Staphylococcus aureus (MRSA) is widely acknowledged, and a number of molecular assays are commercially available. This study evaluated the Xpert MRSA assay, which is run on the GeneXpert real-time PCR platform (Cepheid) for use in a clinical laboratory. The following parameters were investigated: (i) the limits of detection (LoDs) for four MRSA strains; (ii) the ability to detect isolates of MRSA from a collection representative of MRSA in Ireland since 1974 ( n = 114) and the ability to detect control strains with staphylococcal cassette chromosome mec types IVa (IV.1.1.1), IVb (IV.2.1.1), IVc (IV.3.1.1), IVd (IV.4.1.1), V (V.1.1.1), V T , and VI; and (iii) performance in a clinical trial with swabs from nose, throat, and groin/perineum sites from 204 patients, where results were compared with those obtained by direct and enrichment cultures. The average LoD of the four test strains was 610 CFU/ml (equivalent to 58 CFU/swab). All 114 MRSA isolates and 7 control strains tested were detected. Sensitivity, specificity, and positive and negative predictive values for clinical specimens from all sites investigated were 90%, 97%, 86%, and 98%, respectively, but throat specimens yielded poor sensitivity (75%). Sensitivity, specificity, and positive and negative predictive values for nasal specimens were 95%, 98%, 90%, and 99%, respectively. Overall, the assay was rapid and easy to perform, but performance might be enhanced by the inclusion of an equivocal interpretive category based on analysis of all available amplification data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oliveira, D. C., Tomasz, A., & de Lencastre, H. (2002) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(02)00227-x · Cited by 494
Chongtrakool, P., Ito, T., Ma, X. X., Kondo, Y., Trakulsomboon, S., Tiensasitorn, C., Jamklang, M., Chavalit, T., Song, J.-H., & Hiramatsu, K. (2006) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.50.3.1001-1012.2006 · Cited by 378
Shore, A., Rossney, A. S., Keane, C. T., Enright, M. C., & Coleman, D. C. (2005) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.49.5.2070-2083.2005 · Cited by 170
Self-citation
Cited by
Guk, K., Keem, J. O., Hwang, S. G., Kim, H., Kang, T., Lim, E.-K., & Jung, J. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.04.016 · Cited by 202
“…its excellent sensitivity of 100–105 CFU/ml, the simple sample preparation is very convenient and highly beneficial for its practical application (Huang et al., 2015; Lee et al., 2013; Malhotra-Kumar et al., 2010a, 2010b; Malhotra-Kumar et al., 2010a, 2010b; Oh et al., 2013; Rossney et al., 2008).”
BackgroundSpecimen Collection, Transport, and Processing: Bacteriology
Baron, E. J. (2015) · Manual of Clinical Microbiology · doi:10.1128/9781555817381.ch18 · Cited by 159
Metadata
- Authors
- Rossney, A. S., Herra, C. M., Brennan, G. I., Morgan, P. M., & O'Connell, B.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2008-10
- Volume
- 46
- Issue
- 10
- Pages
- 3285-3290
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2163801401
- Cited by
- 183
- References
- 3
- FWCI
- 10.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of the Xpert Methicillin-Resistant Staphylococcus aureus (MRSA) Assay Using the GeneXpert Real-Time PCR Platform for Rapid Detection of MRSA from Screening Specimens. https://app.cochat.ai/papers/10.1128/jcm.02487-07
- The paper
- Rossney, A. S., Herra, C. M., Brennan, G. I., Morgan, P. M., & O'Connell, B. (2008). Evaluation of the Xpert Methicillin-Resistant Staphylococcus aureus (MRSA) Assay Using the GeneXpert Real-Time PCR Platform for Rapid Detection of MRSA from Screening Specimens. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.02487-07
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.