CoChat

Mixed Mycobacterium tuberculosis Complex Infections and False-Negative Results for Rifampin Resistance by GeneXpert MTB/RIF Are Associated with Poor Clinical Outcomes

Open access
Zetola, Nicola M., Shin, Sanghyuk S., Tumedi, Kefentse A., Moeti, Keletso, Ncube, Ronald, Nicol, Mark, Collman, Ronald G., Klausner, Jeffrey D., Modongo, Chawangwa · 2014 · Journal of Clinical Microbiology
Cited by 140

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The Xpert MTB/RIF (Xpert) assay is becoming a principal screening tool for diagnosing rifampin-resistant Mycobacterium tuberculosis complex (MTBC) infection. However, little is known about the performance of the Xpert assay in infections with both drug-sensitive and drug-resistant strains (mixed MTBC infections). We assessed the performance of the Xpert assay for detecting rifampin resistance using phenotypic drug sensitivity testing (DST) as the reference standard in 370 patients with microbiologically proven pulmonary tuberculosis. Mixed MTBC infections were identified genetically through 24-locus mycobacterial interspersed repetitive-unit–variable-number tandem-repeat (MIRU-VNTR) analysis. Logistic regression was used to identify the factors associated with poor (defined as treatment failure, default, and death from any cause) or good (defined as cure or successful treatment completion) clinical outcomes. The analytic sensitivity of the Xpert assay for detecting rifampin resistance was assessed in vitro by testing cultures containing different ratios of drug-sensitive and drug-resistant organisms. Rifampin resistance was detected by the Xpert assay in 52 (14.1%) and by phenotypic DST in 55 (14.9%) patients. Mixed MTBC infections were identified in 37 (10.0%) patients. The Xpert assay was 92.7% (95% confidence interval [CI], 82.4% to 97.9%) sensitive for detecting rifampin resistance and 99.7% (95% CI, 98.3% to 99.9%) specific. When restricted to patients with mixed MTBC infections, Xpert sensitivity was 80.0% (95% CI, 56.3 to 94.3%). False-negative Xpert results (adjusted odds ratio [aOR], 6.6; 95% CI,1.2 to 48.2) and mixed MTBC infections (aOR, 6.5; 95% CI, 2.1 to 20.5) were strongly associated with poor clinical outcome. The Xpert assay failed to detect rifampin resistance in vitro when <90% of the organisms in the sample were rifampin resistant. Our study indicates that the Xpert assay has an increased false-negative rate for detecting rifampin resistance with mixed MTBC infections. In hyperendemic settings where mixed infections are common, the Xpert results might need further confirmation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.02489-13

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Zetola, N. M., Shin, S. S., Tumedi, K. A., Moeti, K., Ncube, R., Nicol, M., Collman, R. G., Klausner, J. D., & Modongo, C.
Venue
Journal of Clinical Microbiology
Published
2014-07
Volume
52
Issue
7
Pages
2422-2429
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2050135352
Cited by
140
References
3
FWCI
8.22
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.