CoChat

Assessment of MagNA Pure LC Extraction System for Detection of Human Papillomavirus (HPV) DNA in PreservCyt Samples by the Roche AMPLICOR and LINEAR ARRAY HPV Tests

Stevens, Matthew P., Rudland, Elice, Garland, Suzanne M., Tabrizi, Sepehr N. · 2006 · Journal of Clinical Microbiology
Cited by 55

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Roche Molecular Systems recently released two PCR-based assays, AMPLICOR and LINEAR ARRAY (LA), for the detection and genotyping, respectively, of human papillomaviruses (HPVs). The manual specimen processing method recommended for use with both assays, AmpliLute, can be time-consuming and labor-intensive and is open to potential specimen cross-contamination. We evaluated the Roche MagNA Pure LC (MP) as an alternative for specimen processing prior to use with either assay. DNA was extracted from cervical brushings, collected in PreservCyt media, by AmpliLute and MP using DNA-I and Total Nucleic Acid (TNA) kits, from 150 patients with histologically confirmed cervical abnormalities. DNA was amplified and detected by AMPLICOR and the LA HPV test. Concordances of 96.5% (139 of 144) (κ = 0.93) and 95.1% (135 of 142) (κ = 0.90) were generated by AMPLICOR when we compared DNA extracts from AmpliLute to MP DNA-I and TNA, respectively. The HPV genotype profiles were identical in 78.7 and 74.7% of samples between AmpliLute and DNA-I or TNA, respectively. To improve LA concordance, all 150 specimens were extracted by MP DNA-I protocol after the centrifugation of 1-ml PreservCyt samples. This modified approach improved HPV genotype concordance levels between AmpliLute and MP DNA-I to 88.0% ( P = 0.043) without affecting AMPLICOR sensitivity. Laboratories that have an automated MP extraction system would find this procedure more feasible and easier to handle than the recommended manual extraction method and could substitute such extractions for AMPLICOR and LA HPV tests once internally validated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.02608-05

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 55

Metadata

Authors
Stevens, M. P., Rudland, E., Garland, S. M., & Tabrizi, S. N.
Venue
Journal of Clinical Microbiology
Published
2006-07
Volume
44
Issue
7
Pages
2428-2433
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2153673975
Cited by
55
References
1
FWCI
4.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of MagNA Pure LC Extraction System for Detection of Human Papillomavirus (HPV) DNA in PreservCyt Samples by the Roche AMPLICOR and LINEAR ARRAY HPV Tests. https://app.cochat.ai/papers/10.1128/jcm.02608-05
The paper
Stevens, M. P., Rudland, E., Garland, S. M., & Tabrizi, S. N. (2006). Assessment of MagNA Pure LC Extraction System for Detection of Human Papillomavirus (HPV) DNA in PreservCyt Samples by the Roche AMPLICOR and LINEAR ARRAY HPV Tests. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.02608-05

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.