The DOI matches its Crossref record.
Comparison of the Biofire FilmArray RP, Genmark eSensor RVP, Luminex xTAG RVPv1, and Luminex xTAG RVP Fast Multiplex Assays for Detection of Respiratory Viruses
Open accessAbstract
There are several U.S. FDA-cleared molecular respiratory virus panels available today, each with advantages and disadvantages. This study compares four multiplex panels, the BioFire Diagnostics FilmArray RP ( r espiratory p anel), the GenMark Dx eSensor RVP ( r espiratory v iral p anel), the Luminex xTAG RVPv1, and the Luminex xTAG RVP fast. Three hundred specimens (200 retrospective and 100 consecutive) were tested using all four platforms to determine performance characteristics. The overall sensitivity and specificity, respectively, and 95% confidence interval (CI; in parentheses) for each panel were as follows: FilmArray RP, 84.5% (79.2, 88.6) and 100% (96.2, 100); eSensor RVP, 98.3% (95.5, 99.5) and 99.2% (95.4, 100); xTAG RVPv1, 92.7% (88.5, 95.4) and 99.8% (96.0, 100); and xTAG RVP fast, 84.4% (78.5, 88.9) and 99.9% (96.1, 100). The sensitivity of each assay fluctuated by viral target, with the greatest discrepancies noted for adenovirus and influenza virus B detection. Hands-on time and time to result were recorded and ease of use was assessed to generate a complete profile of each assay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Adenovirus Infections in Immunocompetent and Immunocompromised Patients
Lion, T. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00116-13 · Cited by 861
Massively multiplexed nucleic acid detection with Cas13
Ackerman, C. M., Myhrvold, C., Thakku, S. G., Freije, C. A., Metsky, H. C., Yang, D. K., Ye, S. H., Boehm, C. K., Kosoko-Thoroddsen, T.-S. F., Kehe, J., et al. (2020) · Nature · doi:10.1038/s41586-020-2279-8 · Cited by 803
Brendish, N. J., Malachira, A. K., Armstrong, L., Houghton, R., Aitken, S., Nyimbili, E., Ewings, S., Lillie, P. J., & Clark, T. W. (2017) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(17)30120-0 · Cited by 335
Syndromic Panel-Based Testing in Clinical Microbiology
Ramanan, P., Bryson, A. L., Binnicker, M. J., Pritt, B. S., & Patel, R. (2018) · Clinical Microbiology Reviews · doi:10.1128/cmr.00024-17 · Cited by 308
Emerging Technologies for the Clinical Microbiology Laboratory
Buchan, B. W., & Ledeboer, N. A. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00003-14 · Cited by 297
Metadata
- Authors
- Popowitch, E. B., O'Neill, S. S., & Miller, M. B.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2013-05
- Volume
- 51
- Issue
- 5
- Pages
- 1528-1533
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2082571397
- Cited by
- 249
- References
- 0
- FWCI
- 18.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of the Biofire FilmArray RP, Genmark eSensor RVP, Luminex xTAG RVPv1, and Luminex xTAG RVP Fast Multiplex Assays for Detection of Respiratory Viruses. https://app.cochat.ai/papers/10.1128/jcm.03368-12
- The paper
- Popowitch, E. B., O'Neill, S. S., & Miller, M. B. (2013). Comparison of the Biofire FilmArray RP, Genmark eSensor RVP, Luminex xTAG RVPv1, and Luminex xTAG RVP Fast Multiplex Assays for Detection of Respiratory Viruses. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.03368-12
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.