Screening of Urine Cultures by Three Automated Systems
Open accessThe DOI matches its Crossref record.
Abstract
A study was conducted to compare three automated systems and the Gram stain for their ability to detect significant bacteriuria. A total of 1,000 urine specimens were evaluated by Autobac MTS (General Diagnostics), Auto Microbic system (AMS; Vitek Systems, Inc.), and MS-2 (Abbott Laboratories) and compared with a semiquantitative culture plate method. Two hundred thirty-nine (23.9%) specimens had colony counts of >10 5 colony-forming units (CFU)/ml by the culture plate method (group I). Of these, 204 (85.3%) were positive by Autobac, 198 (82.8%) were positive by AMS, and 179 (74.9%) were positive by MS-2. When pure cultures of diphtheroids, lactobacilli, and viridans streptococci not group D were considered contaminants and therefore excluded, there were 118 specimens containing pure cultures of probable pathogens. The percentage of significant isolates detected was 97.4% (115 of 118) by the Gram stain, 96.6% (114 of 118) by Autobac, and 95.8% (113 of 118) by AMS and MS-2. The average detection time for all organisms was 2.2 h by Autobac, 6.1 h by AMS, and 1.8 h by MS-2; therefore, all three methods were more rapid than the 18- to 24-h standard plate culture method. One hundred sixty-one (16.1%) specimens had colony counts of 10 4 to 10 5 CFU/ml (group II). The probable pathogens not detected in this group were two (1.2%) by Autobac and MS-2 and three by AMS (1.9%). The average detection time for group II was 4.2 h by Autobac, 8.9 h by AMS, and 3.8 h by MS-2. Six hundred specimens had colony counts of <10 4 CFU/ml. Of these, 188 had colony counts equal to 10 3 and <10 4 CFU/ml (group III), and 412 cultures were below detectable limits by the standard plate method (group IV). Less than 37 and 15% of groups III and IV, respectively, were detected by instrumentation. Average detection times for groups III and IV were 4.6 and 4.8 h by Autobac, 10 and 11 h by AMS, and 4.2 and 4.4 h by MS-2. The cost of supplies and technical time with Gram stain, Autobac, and MS-2, when used as screening methods, were comparable and considerably less expensive than for the reference method. The AMS was the least expensive system when the cost for identifying probable pathogens was included.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laboratory Diagnosis of Urinary Tract Infections in Adult Patients
Wilson, M. L., & Gaido, L. (2004) · Clinical Infectious Diseases · doi:10.1086/383029 · Cited by 680
“>105 cfu/mL 81-97 71-96 31-90 92-100 [34-36, 38] s_104 cfu/mL 86-96 75-99 59-98 80-99 [28, 40]”
BackgroundEndotoxemia: Methods of detection and clinical correlates
Hurley, J. C. (1995) · Clinical Microbiology Reviews · doi:10.1128/cmr.8.2.268 · Cited by 318
Controversies in the laboratory diagnosis of community-acquired urinary tract infection
Morgan, M. G., & McKenzie, H. (1993) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/bf01970954 · Cited by 73
Winquist, A. G., Orrico, M. A., & Peterson, L. R. (1997) · American Journal of Clinical Pathology · doi:10.1093/ajcp/108.5.515 · Cited by 22
Metadata
- Authors
- Pezzlo, M. T., Tan, G. L., Peterson, E. M., & De La Maza, L. M.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1982-03
- Volume
- 15
- Issue
- 3
- Pages
- 468-474
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W1798009250
- Cited by
- 67
- References
- 0
- FWCI
- 10.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Screening of Urine Cultures by Three Automated Systems. https://app.cochat.ai/papers/10.1128/jcm.15.3.468-474.1982
- The paper
- Pezzlo, M. T., Tan, G. L., Peterson, E. M., & De La Maza, L. M. (1982). Screening of Urine Cultures by Three Automated Systems. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.15.3.468-474.1982
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.